Junction Box Installation - Quadra-Fire Expression 36 Owner's Manual

Qv36a-fb
Hide thumbs Also See for Expression 36:
Table of Contents

Advertisement

Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.
Wall Switch
This appliance comes with a QWSK-MLT wall switch kit
to control all the functions of the appliance. The wiring
instructions are included in the manual bag as a separate
addendum and included with the wall switch kit. Follow
the instructions to install the wall switch kit.
This appliance has standard fi rebox lighting. The 20 watt
halogen bulbs are not factory installed. The lights are ac-
cessible from under the fi rebox in the valve area.
To Replace a Light Bulb:
The lights are shipped in boxes in the light enclosures.
Reach behind the valve and locate the light boxes. Cut
the rubber band and slide out the back of the light box.
Remove the light bulb from the box and install it in the
socket. Replace the back of the enclosure.
Figure 10.2 Light enclosure
32
Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. Q • 2/10
D. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
• Remove the cover plate located on the outer shell - right
side (see Figure 10.3).
• Install the supplied Romex™ connector in the cover
plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the appli-
ance:
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 10.3).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle
to the outer shell.
GRN wire
inside box
Figure 10.3 Junction Box Detail
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
to GRN screw with
GRN wire
Note: Do NOT wire
110VAC to wall switch.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qv36a-fbExpression 36 qv36a-fb

Table of Contents