C. Junction Box Installation
FEED PLUG
THROUGH HOLE
JUNCTION
BOX
SCREW
PROVIDED
Figure 10.3 Junction box installation
Optional Accessories
Connecting the electrical junction box is required if using
a blower or remote.
• Plug the cord into a convenient outlet.
• Must use cord supplied.
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
26
INSERT STRAIN RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
SIDEWALL
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08
D. Fan Replacement
On units already installed removal of decorative front,
surround and gas insert is required.
• Detach fl exible liner from back of unit if insert is in-
stalled.
• Remove the four screws on the cover plate (see Figure
10.4).
POWER
CORD
Figure 10.4
• Remove the old fan. See Figure 10.5.
• Place the new fan in between the bend up tabs.
• Install and wire the fan per instruction shipped with the
fan.
• The ground wire of the fan can clip on the side of the
base pan.
• Reinstall the cover plate back on the unit. Make sure the
fan does not make contact with the back wall to prevent
noise from vibration.
COVER
FAN
PLATE
GROUND
WIRE