CAMERA SETUPS AND CABLE CONNECTIONS

DOME CAMERA SETUPS

6.2
Before connecting the Dome Camera to other devices of CCTV system, please complete the Dome Camera's ID
and communication switch settings. These switches are located on the bottom of the Dome Camera.

SWITCH DEFINITION

6.2.1
Please refer to the following figure and table for switch location and definitions.

COMMUNICATION SWITCH SETTING

6.2.2
The analog Dome Camera's communication switches are specified in the table below.
Communication Switch
SW1
SW2
SW3
SW4
SW5
SW6
RS-485 is the interface that communicates the Dome Camera and its control device; for this reason, the RS-485
setup of the dome and the control device must be the same. The RS-485 default setting is half-duplex (see the dia-
gram follows). Please do not change the default setting without qualified specialist or supplier's notice. As for the SW
3 and SW 4, they are used for termination and Line Lock adjustment respectively. The SW 5 is mainly used when
users want to restore the camera to the factory default status; moreover, once firmware upgrade is carried out, users
also need to reset the SW 5 afterward.
40 | ISE-XH30(36)ZWDN650 FD
A
Camera Control Protocol Switch
B
Communication Switch
C
None
D
22-Pin Connector
E
ID Switch
F
Reserved
G
ISP Connector (for FW upgrade)
RS-485 Setting
Termination
Line Lock
Factory Default Reset
Reserved
RS-485 Setting
Half-duplex
ID SETTING
6.2.3
Please change the analog Dome Camera's ID if there is more than one Dome Camera on the same installation site.
Use the switch to change your Speed Dome Camera's ID by turning the arrow to the desired number respectively.
For instance, if the camera's ID is 123, the ID switch should be set as below.
Centesimal Digit
Decimal Digit
Single Digit
Note: No two Dome Cameras should be given the same ID, or communication conflict may occur; The num-
ber "0" should locate upwards as shown in above diagram for correct switch definition.

CAMERA CONTROL PROTOCOL SETUP

6.2.4
Define the protocol you are going to use basing on the devices of your surveillance system. Generally, use one pro-
tocol even the devices are provided from different manufacturers. Use the switch to set your camera control protocol
and the baud rate. Refer to the table below and turn the arrow to choose a protocol for your Dome Camera.