4-3. NOISE CRITERION CURVES
PKFY-P06NAMU-E
PKFY-P08NAMU-E
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
250
BAND CENTER FREQUENCIES, Hz
PKFY-P18NFMU-E
PKFY-P24NFMU-E
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
250
BAND CENTER FREQUENCIES, Hz
Unit
3.3ft
3.3ft
SPL(dB)
NOTCH
LINE
High
36
Medium1
35
Medium2
33
Low
32
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
500
1000
2000
4000
8000
SPL(dB)
LINE
NOTCH
High
45
Low
39
500
1000
2000
4000
8000
Wall
Ambient temperature 80°F
PKFY-P12NGMU-E
PKFY-P15NGMU-E
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
PKFY-P30NFMU-E
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
NC-20
CONTINUOUS
NOISE
10
63
125
15
SPL(dB)
NOTCH
High
Medium1
Medium2
Low
250
500
1000
2000
BAND CENTER FREQUENCIES, Hz
SPL(dB)
NOTCH
High
49
Low
46
250
500
1000
2000
BAND CENTER FREQUENCIES, Hz