Water Heater; Shower System - Sea Ray 260 Sundancer Owner's Manual

Hide thumbs Also See for 260 Sundancer:
Table of Contents

Advertisement

S
ECTION
E. W
H
ATER
EATER
The water heater is located in the port side of the
engine room. It operates on the 120 volt (or 220
volt) dockside system or generator and has a circuit
breaker on the main distribution panel located in
the cabin.
!
WARNING
Make certain the hot water lines are air free, indicating
the water heater is full. Damage will occur to water
heater if it is not full when turned on.
The water heater has a check valve to prevent hot
water from back-washing into the cold water source
and a pressure relief valve to avoid damage to the
heater from over pressure of excessive
temperature.
The hot water exchanger is designed to heat water
without having to turn the water heater on. It works
by pumping water from the engine cooling system,
out the intake manifold to the water heater. It is
then circulated through a coil inside the water heater
where it heats the potable water. The water from
the engine then exits the water heater and returns
to the engine through the engine water pump.
I
S
-
NITIAL
TART
UP OR AFTER
1.
Make sure the WATER HEATER breaker is
OFF.
2.
Make sure drain and pressure relief valve is
closed.
3.
Fill the heater with water by turning ON the
WATER PUMP breaker.
4.
Open the hot water faucets until all air is
eliminated from the system.
5.
Make certain the heater is full of water.
COMPLETE FAILURE OF THE HEATING
ELEMENTS WILL RESULT IF THEY ARE
NOT COMPLETELY IMMERSED IN WATER
AT ALL TIMES.
6.
Turn the WATER HEATER breaker ON.
The water heater is equipped with an adjustable
260 Sundancer
(275 Sundancer
®
7 • O
PTIONS
W
INTERIZATION
)
®
& A
CCESSORIES
combination temperature regulating control and
manual reset high limit device located behind the
lower access cover. ALWAYS DISCONNECT
POWER TO THE UNIT BEFORE REMOVING
THE ACCESS COVER. Refer to the water heater
information in the Owner's Manual Packet for
instructions on adjusting the thermostat.
To maintain water heater properly, drain whenever
the possibility of freezing occurs and frequently
inspect lines and connections for leaks.
REFER
TO
OWNER'S
FOR INSTRUCTIONS
INFORMATION.
F. S
S
HOWER
YSTEM
The shower drains into a self-contained shower
sump containing a pump and float switch.
NOTE: The optional air conditioner condensation
also drains into the shower sump.
The sump pump is fully automatic and is protected
by a breaker on the main DC breaker panel.
Check the pump and float switch for obstructions
and proper working order.
The pump comes on when there is enough water in
the sump to raise the float switch and start the pump.
If it does not come on after one or two gallons of
water drain from the shower, turn the water off and
check the pump and float switch for proper
operation.
After using the shower, it is recommended that you
run a gallon of clean water through the shower drain
to clean out soap residue. Check the pump and float
switch for obstructions and proper working order.