AC Input Voltage Detection
The QuiQ charger automatically detects the AC input voltage and will operate at full power if the voltage is within the
120 to 230 VAC range. The charger also will function outside of that range down to 85 VAC and up to 265 VAC
although charging times will be longer. Outside of the 85 to 265 VAC range, the charger will not operate.
Thermal Cutback
The QuiQ charger operates at full power in ambient temperatures between 32 °F (0 °C) and 86 °F (30 °C). The charger
also will function outside of that range although charging times will be longer.
How To Identify the Charger Algorithm Number
To see the charger algorithm number, initiate the Algorithm Display Mode. To enter Algorithm Display Mode, take
the following steps:
1.
Unplug the AC power supply cord from the wall outlet.
2.
Disconnect the heavy-gauge red wire from the positive (+) post of battery no. 1.
3.
Plug the AC power supply cord into the wall outlet. See following NOTE.
NOTE: When the charger AC cord is connected, LED lights on the charger perform a start-up self-test (LEDs light
up in sequence).
4.
After the start-up self-test, the 80% LED will display a series of flashes that represent the algorithm number
(Figure 28). [Example: Algorithm number 125 is represented as "one flash", pause, "two flashes", pause, "five
flashes".] The charger will not repeat this series of flashes. To see the number again, repeat steps 1 and 3
with a 20 second pause between them.
Figure 28 80% LED Flashes in Algorithm Display Mode