DISCONNECTING THE BATTERIES – ELECTRIC VEHICLES
1.
Disable the vehicle. See Disabling the Vehicle on page 11.
2.
Place Tow/Run switch in the TOW position before disconnecting or connecting the batteries. Failure to heed
this warning can result in a battery explosion or severe personal injury.
3.
Disconnect the batteries, negative (–) cable first, as shown (Figure 3).
4.
After disconnecting the batteries, wait 90 seconds for the controller capacitors to discharge.
CONNECTING THE BATTERIES – ELECTRIC VEHICLES
1.
Ensure the Tow/Run switch is in the TOW position.
2.
Connect the battery cables, positive (+) cable first.
3.
Tighten battery terminals to 110 in·lb (12.4 N·m).
4.
Coat terminals with Battery Terminal Protector Spray (CC PN 1014305) to minimize corrosion.
RECYCLING LEAD-ACID BATTERIES
WARNING
• Lead-acid batteries contain lead (Pb), other metals, acids and other compounds. If improperly handled,
they can contaminate both water and soil, causing environmental damage and personal injury.
Lead-acid batteries are identified by the symbol shown below and should be properly recycled (Figure 4). They cannot
be disposed as municipal waste and must be collected separately. Responsibility for environmental protection must be
shared, not only by the manufacturers of the batteries, but by people who use the batteries as well. Please contact
your nearest Club Car dealer or distributor for information on how to properly recycle your batteries.
1403
Figure 4 Dispose of Lead-acid Batteries Properly