2.2 Mounting a module – desk or rack
The Extender C5 modules can be situated on a desk (or floor) or alternatively, for larger installations, mounted
within optional rack mount chassis units.
Desk mount
Apply the supplied self-adhesive rubber feet to the underside of
the module(s)
Rack mount
Note:
The module switches are not accessible once it is inserted into
the rack, therefore, check all settings before insertion.
1
Place the rack securing plate (available as a separate kit) onto the front of the module and secure it with
the two countersunk screws.
2
Orientate the module on its side so that its labelled face is the correct way up and the securing plate is
facing away from the rack.
3
Slide the module into the required rack position. The rectangular cut-out in the front upper lip of the rack
allows the two screws on the module's upper edge to slide through.
4
The rack mount chassis has a series of holes in its floor that are spaced to accommodate the two
screws on the module's lower edge. Ensure that the screws correctly locate into the two holes of the
chosen slot. The rack securing plate on the module should now be flush with the front of the rack mount
chassis.
5
Use the third (pan-head) screw, in the top hole of the rack securing plate to fasten the module to the
rack.
LINDY KVM Extender C5 Pro
Installation and Use
page 12