INSTALLATION AND OPERATING MANUAL
ITYS
1-10 kVA
IOMITYTWXX00-GB_00 - 03.2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITYS and is the answer not in the manual?

Questions and answers

Summary of Contents for socomec ITYS

  • Page 1 INSTALLATION AND OPERATING MANUAL ITYS 1-10 kVA IOMITYTWXX00-GB_00 - 03.2008...
  • Page 2 You have purchased a high professional UPS to provide you protection against black-outs and electrical impuri- ties. The ITYS range has been designed specifically for the protection of critical electronics and I.T. consumers such as servers, UNIX workstations or networking peripherals which could suffer hardware damage and data losses as a result of the disturbance deriving from the electrical mains.
  • Page 3: Table Of Contents

    10.4 Operation with manual by-pass (ITYS 6 kVA, 10 kVA only) ......
  • Page 5: Certificate And Conditions Of Warranty

    During the warranty period, SOCOMEC UPS may, at its discretion, decide to repair the product or replace the defective parts with new parts or with used parts that are equivalent to new parts in terms of functions and performance.
  • Page 6 12 months from the date of purchase. Under no circumstances will SOCOMEC UPS be responsible for damages (including, without limitations, dam- age for loss of earnings, interruption of activity, loss of data or other economic losses) deriving from the use of this product.
  • Page 7: Safety Standards

    Only for ITYS 1-2-3 kVA: as the mains cable of the UPS is considered a disconnecting device, the mains socket to which the UPS is connected and/or the rear of the UPS must be accessible and easy to disconnect.
  • Page 8 UPS. Only for ITYS 6-10 kVA: If the UPS does not have an automatic protection device against current back-feed, the operator/installer must:...
  • Page 9: General Description

    (typical of IT users) from being reflected on the power supply line. In the event of a black-out, ITYS provides for generation of the output voltage without any disturbance, even transient, drawing the power from the internal batteries. During normal operation with the mains line present, ITYS recharges the batteries fully automatically and independently.
  • Page 10: Unpacking And Installation

    ITYS UNPACKING AND INSTALLATION 1-10 kVA 4.1 ENVIRONMENTAL REQUIREMENTS FOR INSTALLATION. Install the UPS after first checking the following: to direct sunlight. data can be found on the data plate. serial interface. CAUTION IF DAMAGED. BATTERIES, NON SPILLABLE. Packages, crushed, punctured, or torn such that contents are revealed must be set aside in an isolated area and inspected by a qualified person.
  • Page 11: Unpacking Of The Ups

    ITYS UNPACKING AND INSTALLATION 1-10 kVA 4.2 UNPACKAGING OF THE UPS. 4.2.1 ITYS 1 kVA, 2 kVA, 3 kVA. 4.2.1-1 4.2.1-2 4.2.1-3 4.2.2 ITYS 6 kVA, 10 kVA. 4.2.2-1 4.2.2-2 4.2.2-3 4.2.2-4 IOMITYTWXX00-GB_00...
  • Page 12: Front View

    ITYS FRONT VIEW 1-10 kVA Mimic panel. ON button button and silence buzzer 6 kVA 2 kVA 1 kVA 10 kVA 3 kVA IOMITYTWXX00-GB_00...
  • Page 13: Rear View

    ITYS REAR VIEW 1-10 kVA 1 kVA 2 kVA Legend. A RS232 serial port (JBUS protocol) B Fan C Input protection D ADSL/modem/telephone line protection E Input socket (IEC 320) F Slot for optional communication boards G Output sockets (IEC 320)
  • Page 14 ITYS REAR VIEW 1-10 kVA Legend. A RS232 serial port (JBUS protocol) B Fan B1 Fan (10 kVA only) C Input protection (magneto-thermal) D Input and output terminal board E Cable couplings F Slot for optional communication boards G Manual by-pass...
  • Page 15: Connections

    ITYS CONNECTIONS 1-10 kVA Connection to the mains supply and the load should be effected by using cables of an appropriate thickness and which conform to the standards in force. A distribution panel must be set up (if there is not one already) which can be used to isolate the mains upstream of the UPS.
  • Page 16 ITYS CONNECTIONS 1-10 kVA The installation and the system must comply with national plant regula- tions. If a differential switch is installed on the mains power switch (op- tional), it must be inserted upstream from the distribution panel. Mains Output CAUTION! Use selective type differentials.
  • Page 17: External Battery Cabinet Connection (For Lb Models Only)

    ITYS EXTERNAL BATTERY CABINET CONNECTION (for LB models only) 1-10 kVA 8.1 IMPORTANT. WARNING! Danger of explosion if the batteries are replaced with others of the wrong type. exclusively to specialist disposal companies. As provided for by the local laws in force, batteries must not be disposed of with other industrial or domestic waste.
  • Page 18: Modular Battery Cabinet

    ITYS EXTERNAL BATTERY CABINET CONNECTION (for LB models only) 1-10 kVA 8.3 MODULAR BATTERY CABINET. 6-10 kVA 2-3 kVA 8.4 BATTERY CABINET SPECIFIC FOR ITYS. 1-2-3 kVA 6-10 kVA IOMITYTWXX00-GB_00...
  • Page 19: Mimic Panel

    ITYS MIMIC PANEL 1-10 kVA The mimic panel located on the front of the UPS provides all the information relating to the unit’s operating status. Legend. A Yellow LED. By-pass mode. B Yellow LED. Power supply from battery (battery mode).
  • Page 20: Modes Of Operation

    The UPS can also be used with batteries that are not fully charged, but back-up time will be reduced if there is a mains power failure. 10.2 START-UP AND SHUTDOWN ITYS 1 kVA, 2 kVA, 3 kVA. 10.2.1 Start-up with mains present.
  • Page 21: Shutdown With Mains Present

    ITYS MODES OF OPERATION 1-10 kVA 10.2.3 Shutdown with mains present. 10.2.3-1 10.2.3-2 10.2.3-3 the other. supply for full shutdown. > 1 sec 10.2.3-4 10.2.4 Shutdown without mains present. 10.2.4-1 10.2.4-2 10.2.4-3 > 1 sec TEST Turn off all the loads, one after the other.
  • Page 22: Start-Up And Shutdown Itys 6 Kva, 10 Kva

    ITYS MODES OF OPERATION 1-10 kVA 10.3 START-UP AND SHUTDOWN ITYS 6 kVA, 10 kVA. 10.3.1 Start-up with mains present. 10.3.1-1 10.3.1-2 10.3.1-3 > 1 sec TEST 10.3.1-4 10.3.1-5 Normal operation. TEST Start-up all the loads, one at a time.
  • Page 23: Shutdown With Mains Present

    ITYS MODES OF OPERATION 1-10 kVA 10.3.3 Shutdown with mains present. 10.3.3-1 10.3.3-2 10.3.3-3 > 1 sec TEST 10.3.3-4 10.3.3-5 10.3.3-6 TEST Remove the mains power supply for full shutdown. IOMITYTWXX00-GB_00...
  • Page 24: Shutdown Without Mains Present

    TEST Turn off all the loads, one after the other. 10.4 OPERATION WITH MANUAL BY-PASS (ITYS 6 kVA, 10 kVA only). If the maintenance bypass is activated using the appropriate procedure, the load is powered directly from the maintenance by-pass, while the UPS is separated from the power supply.
  • Page 25: Operation From Manual By-Pass To Normal Operation (Itys 6 Kva, 10 Kva Only)

    ITYS MODES OF OPERATION 1-10 kVA 10.5 OPERATION FROM MANUAL BY-PASS TO NORMAL OPERATION (ITYS 6 kVA, 10 kVA only). 10.5-1 10.5-2 10.5-3 10.5-4 10.6 BATTERY TEST. The battery test can be activated manually or via the SW (as long as the conditions are right).
  • Page 26: Visual And Acoustic Segnalisations

    ITYS VISUAL AND ACOUSTIC SEGNALISATIONS 1-10 kVA LED ON LED OFF LED flashing Indication of load level (normal operation). 0÷35% 36÷55% 56÷75% 76÷95% 96÷105% Indication of battery capacity (operation on battery mode). 0÷20% every second 21÷40% every 4 seconds 41÷60% every 4 seconds 61÷80%...
  • Page 27 ITYS VISUAL AND ACOUSTIC SEGNALISATIONS 1-10 kVA LED ON LED OFF LED flashing Very high temperature. Irregular inverter operation. Output short-circuit. Other optical signals that may be Other optical signals that may be Other optical signals that may be continuous...
  • Page 28: Communication

    The ITYS UPSs come with RS232 serial communication interfaces and slots for the NetVision card. 12.1 COMMUNICATION SOLUTIONS.
  • Page 29: Rs232 Interface

    ITYS COMMUNICATION 1-10 kVA 12.2 RS232 INTERFACE. Communication with the server can take place directly via the RS232 interface. In addition to local or networked shutdown it is possible to perform full monitoring of the electrical parameters regarding battery status and the automatic programming of the UPS start-up and shutdown procedures.
  • Page 30: Maintenance

    ITYS MAINTENANCE 1-10 kVA WARNING! DANGEROUS electrical voltages are generated inside the UPS. All maintenance operations to be performed SOLELY AND EXCLUSIVELY by authorized personnel. correct maintenance of the battery charge. before switching the UPS off completely (mains present for eight hours consecutively).
  • Page 31: Technical Specifications

    ITYS TECHNICAL SPECIFICATIONS 1-10 kVA Models ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Power (VA) 1000 2000 3000 6000 10000 Power (W) 1400 2100 4200 7000 Electrical specifications - Input ITY-TW010B / LB...