Troubleshooting

If the clothes are not dry after normal drying time:
- Check that the filter is clean. A blocked filter will restrict the airflow.
- Check that you used the correct heat setting and did not overload
the dryer.
- Check that the condenser unit and associated duct work are clean. If
blocked, these will restrict the airflow.
- Check that your dryer is heating - the area below the door should
feel warm to the touch after the first 10-15 minutes of its programme.
- Check that the bottle full warning light is off. If it is on then the bottle
may be full or incorrectly fitted.
If your appliance does not work, check the following points before
contacting CDA Customer Care
C heck that there is power to the appliance.
C heck that the machine is switched on and the door properly
closed.
- Check that the Activate button has been pressed and that the
Display is illuminated.
- Check that the water bottle has been withdrawn from, and replaced
into, the machine. The bottle full warning light should be off.
T his appliance has a resettable cut-out. Check this has not
operated. Press the red button on the right hand side at the
back of your dryer. If the cut-out has operated a sharp "click"
will be heard. This cut-out only operates if the airflow is
severely restricted so make sure the filter is clean and that all other
restrictions are removed before restarting.
C heck the fuse in the moulded plug.