FLASH
CODE
8
9
10
11
As at: 19.03.2004
Meaning
Error in Shark
power module
Communication
error in Shark
system
Unknown error
Incompatible
remote
Solution
Check all cables and connecting plugs
in the Shark system.
Replace power module
Check all cables and connecting plugs
in the Shark system.
Replace remote.
Check all cables and connecting plugs. See "Checking the
The wrong remote type is connected.
Ensure that the power module type
code matches the remote type code.
Page 23
Tornado
Notes
See "Checking the
cables" on page
36
See "Replacing
components of the
ACS or Shark
electronics" on
page 27
See "Checking the
cables" on page
36
See "Replacing
the remote" on
page 38
cables" on page
36
See "Replacing
the remote" on
page 38
See "Replacing
components of the
ACS or Shark
electronics" on
page 27