Burner Valve; Flame Characteristics; Orifice Conversion Kits; Simmer Orifice Burner Replacement - GE Monogram ZDP30_ _H Technical Service Manual

Monogram dual fuel pro ranges and gas cooktops
Table of Contents

Advertisement

Burner Valve

The burner valves are attached to the manifold by
two screws and contains an orifice which sets
the flow rate for the simmer flame. This valve
does not have a low flame adjustment, it is
controlled by the orifice size.

Simmer Orifice Burner Replacement

The simmer burner orifice requires a 4mm socket
to remove it. If necessary a 4mm socket is
available under part # WX05x10006.

Surface Burner Adjustments

Standard adjustments to the air shutter and gas
metering orifices are not possible on sealed
burners.
If burner flames appear to be abnormal, check the
following:
Check gas pressure available to the burners.
The required operating pressure is 5" W.C.P.
Natural Gas or 10" W.C.P. L.P. (Propane) Gas.
Check for drafts entering the burner box from
behind the cooktop.
Check for blockage or partial blockage of the
orifice. Inspect the orifice to be sure it has
been drilled on center and is free of debris or
burrs.
Check the burner alignment per
.
Alignment
If the cause of the problem cannot be found,
installing an orifice with smaller diameter
openings may solve the problem. In high
altitude (above 6000 ft.) installation, the
orifices will usually have to be downsized.

Flame Characteristics

Burner flames should be blue and stable with no
yellow tips. (Yellow tipping may be normal for LP
gas.) The flame should not have excessive noise
or lifting of the flame from the burner. If any of
these conditions exist, check the burner ports for
blockage.

Orifice Conversion Kits

Burner orifice conversion kits are available for:
Converting burner orifices from LP to Natural
Gas and from Natural Gas to LP
Installation at high altitudes
Natural/LP Conversion Kit - Order part number
WB49X10132
LP/Natural Conversion Kit - Order part number
WB49X10133
High Altitude Conversion Kit – Order part number
WB49X10130
ORIFICE/JET SIZES
BURNER
D BURNER
D BURNER
GRILL/GRIDDLE
GRILL/GRIDDLE
Burner
HIGH ALTITUDE CONVERSION
BURNER
D BURNER
D BURNER
GRILL/GRIDDLE
GRILL/GRIDDLE
– 11 –
Main Flame
Simmer Flame
ORIFICE/JET SIZES
ORIFICE (mm)
RATE (BTU/HR)
GAS MAIN SIMMER Valve
HI
NG
1.85
0.57 mm
0.57
17k
LP
1.18
0.34 mm
0.34
15k
NG
1.93
–––––
0.94
18k
LP
1.32
–––––
0.47
18k
Recomme ded Orifice ize for Hi h Altit de I tallatio
Sea Level 3000 ft. 6000 ft.
GAS
MAIN Orifice (mm)
NG
1.85
1.78
1.61
LP
1.18
1.09
1.07
NG
1.93
1.85
1.70
LP
1.32
1.32
1.18
LO
SIM
2700
1300 185 P
2500
1200 118 E
6000
––––
48 –––
6000
––––
55 –––