Hitachi Ultrastar 15K73 Reference Manual page 264

3.5 inch magnetic disk drive scsi interface specification
Hide thumbs Also See for Ultrastar 15K73:
Table of Contents

Advertisement

7
27 00
6
29 00
6
29 01
6
29 02
6
29 03
6
29 04
6
29 05
6
29 06
6
2A 00
2 or 6
2A 01
6
2A 02
6
2A 03
6
2A 04
6
2A 05
6
2F 00
2 or 3
31 00
2 or 3
31 01
6 SENSE DATA
Write Protected
Power On or Reset
or Bus Device Reset
Occurred
Power On Reset
Occurred
SCSI Bus Reset
Occurred
Bus Device Reset
Occurred
Device Internal
Reset
Mode Changed from
LVD to SE
Mode Changed from
SE to LVD
Parameters
Changed
Mode Parameters
Changed
Log Parameters
Changed
Reservations
Preempted
Reservations
Released
Registrations
Preempted
Commands Cleared
by Another Initiator
Medium Format
Corrupted
Format Command
Failed
The specified drive was write-protected.
A power-on reset occurred.
A Bus Device Reset message was issued.
An SCSI bus reset occurred.
(Not Occurred)
A power-on reset occurred.
An SCSI bus reset occurred.
A Bus Device Reset message was issued.
A device internal reset occurred.
Mode changed from LVD to SE.
Mode changed from SE to LVD.
The Mode/Log parameters were altered.
E. g., Mode Select command altered
parameters.
E.g., Mode/Log parameters were reset by a
Not Ready to Ready transition of the drive.
The mode parameter has been changed.
The Log parameters have been changed.
The reservation key has been cleared.
The reservation has been cleared.
The persistent reservation has been
preempted.
The executing or queuing commands have
been cleared by another initiator.
The medium has not been formatted
properly.
It is necessary to reformat the medium with
a FORMAT UNIT command.
A Format command completed in the
abnormal condition.
It is necessary to reformat the medium with
a FORMAT UNIT command.
OEM MANUAL:K6602594
Revision: 1 / Date: 2003.03.06
Page: 264 / 273