Hitachi Ultrastar 15K73 Reference Manual page 217

3.5 inch magnetic disk drive scsi interface specification
Hide thumbs Also See for Ultrastar 15K73:
Table of Contents

Advertisement

The defects specified in the REASSIGN BLOCKS command are added to the G list
(Grown Defect List) at the normal end of this command.
Precautions on the host computer side;
When the information bytes of the sense data are reported as valid (Valid bit = 1),
the host computer should issue another Reassign Blocks command with the
reported block address added to the defect descriptors.
When the sense data is received with the logical block address (except
FFFFFFFF
another Reassign Blocks command with the defect descriptors removed the defect
blocks of less local block address number than the reported one.
REASSIGN BLOCKS:(07h)
5 COMMAND DESCRIPTIONS
) in the command specific bytes, the host computer should issue
H
OEM MANUAL:K6602924
Revision: 1 / Date: 2003.03.06
Page: 217 / 273