[ Mode Page 7
Table 5.46 Verify Error Recovery Page (Page Code = 7
Bit
Byte
0
Reserved
1
2
3
4
5
6
7
8
9
10
11
This page specifies the error recovery parameters the controller shall use during
the verify operation of the VERIFY command and the WRITE AND VERIFY
command.
The EER, PER, DTE and DCR bits are defined in the descriptions preceded by
Table 5.40. The combinations of these bits are defined in Table 5.41.
The Verify Retry Count, Verify Correction Span and Verify Recovery Time Limit
are also similarly defined except that these are used at the verify operation.
The automatic reallocation is not applied to the WRITE AND VERIFY command
and the VERIFY command execution.
MODE SELECT:(15h)
5 COMMAND DESCRIPTIONS
]
H
7
6
5
SPF
0
0
0
0
0
0
Reserved
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Verify Recovery Time Limit (MSB)
Verify Recovery Time Limit (LSB)
4
3
Page Code(07
0
0
Page Length(0A
H
0
1
EER
0
Verify Retry Count
Verify Correction Span
Reserved
0
0
Reserved
0
0
Reserved
0
0
Reserved
0
0
Reserved
0
0
OEM MANUAL:K6602924
)
H
2
1
)
H
1
1
)
0
1
PER
DTE
0
0
0
0
0
0
0
0
0
0
Revision: 1 / Date: 2003.03.06
Page: 138 / 273
0
1
0
DCR
0
0
0
0
0