Jacuzzi J - 415 Owner's Manual page 97

J-400 collection
Table of Contents

Advertisement

WARNING:
!
scratch the quartz tube surface.
9. Rinse the quartz tube with clean water to completely remove any
cleaning products that were used in step 4.
10. Replacing quartz tube: You will notice that the new quartz tube
does not have a black cushion on the domed end as the old quartz
tube does. This is normal as the cushion was provided with the
original quartz tube to protect it from breakage during transportation.
Install the black seal ring (13) over the opened end of the quartz
tube. Place the new quartz tube (2) into the water chamber (1) with
the domed end first making sure it is inserted and seated inside the
quartz end holder. Only a small portion will be exposed when it is
seated correctly.
11. Reinstall the compression washer (6) over the open end of the quartz
tube (2). Push it against the quartz black seal ring (13).
12. Reinstall and hand tighten the quartz seal compression nut (7) by
turning it clockwise.
13. Refill your spa.
14. System Test 1: Assure there is no water dripping from the seal
compression nut (7). If water is visible, STOP and tighten the
compression nut (7) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 13. Make sure there
is no water leaking before proceeding to step 15.
15. System Test 2: Turn breaker back ON. Turn on the pump to
circulate the water through the CLEARRAY System. Wait for 5
minutes and assure no water is dripping. If water is visible, STOP, fix
the leak by repeating quartz tube maintenance process from step 1
through step 14. Make sure there is no water visible and turn the
pump and breaker oFF beFore proceeding to step 16.
16. Reconnect the lamp socket (5) to the new UV lamp (4) make sure
you use the latex glove provided when handling the UV lamp.
Align pins on UV lamp (4) to the receptacle holes on the lamp
Note:
socket (5) before inserting the pins completely into socket holes. Failure
to do so will damage the UV lamp.
WARNING:
YOUR BARE HAND. Oil on your skin will cause hot spot on
!
the UV lamp and shorten the life of your UV lamp. Use the
provided latex glove to handle the UV lamp.
17. Slide the new UV lamp (4) back inside the quartz tube, Figure 3.
18. Reinstall the black lamp boot (8) back over the quartz seal
compression nut (7).
19. Reinstall the enclosure cover (10) with gasket (9) and secure with
the screws.
20. Reconnect the CLEARRAY System to the controller and turn on the
power to the spa.
21. Properly dispose of the old UV lamp.