Jacuzzi J - 400 SERIES J - 460 Owner's Manual

Jacuzzi J - 400 SERIES J - 460 Owner's Manual

J-400 series
Table of Contents

Advertisement

Owner's manual
J - 4 0 0 ™
s e r i e s
J - 460
J - 465
J - 470
J - 480
2530-442u rev. a

Advertisement

Table of Contents
loading

Summary of Contents for Jacuzzi J - 400 SERIES J - 460

  • Page 1 Owner’s manual J - 4 0 0 ™ s e r i e s J - 460 J - 465 J - 470 J - 480 2530-442u rev. a...
  • Page 2 ADDENDUM Jacuzzi J-400 Series Owners Manual, #2530-442U Your new hot tub includes one of two stereo remote styles. Both remotes function 100% identically and contain only minor cosmetic differences outlined below: Style A Cosmetic Differences Between Remotes 1. The hand held remote provides you the ability to select the light system color mode. Remote Style A includes a light “MODE”...
  • Page 3 Attention New Spa Owner! Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa. These functions are listed below in an attempt to suppress any operational concerns you may have during the first 24 hours of ownership! Also listed below are important maintenance recommendations you should observe on a regular basis to protect your new investment.
  • Page 4: Table Of Contents

    Adjusting RX Jets ... 27 10.10 WaterColour™ Waterfall Control ... 28 10.11 Air Controls ... 28 10.12 Optional J-1000™ Jacuzzi Audio System... 28 10.13 J-480 Massage/Waterfall Selector Diagram ... 29 10.14 J-480 Air Controls Diagram ... 30 10.15 J-470 Massage/Waterfall Selector Diagram ... 31 10.16 J-470 Air Controls Diagram ...
  • Page 5 50 Hz J-460/J-465/J-470/J-480 wiring Diagram ... 56 19.0 Typical spa wiring Diagrams a-B (north american 60Hz models Only) ... 57 20.0 Optional Jacuzzi J-1000 audio system™ stereo system Features ... 58 20.1 Sound System Controls ... 58 20.2 Sound System Operation ... 59 20.3...
  • Page 6: Important Spa Owner Information

    Important spa Owner Information Your Jacuzzi ® spa is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the spa for efficient operation, an uncovered spa surface directly exposed to sunlight and high temperatures for an extended period is subject to permanent damage.
  • Page 7: Important Safety Instructions For All Spa Owners

    J-400 Series Important safety Instructions for all spa Owners reaD anD FOllOw all InsTruCTIOns CareFullY! This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB Safety Act). When installing and using this spa, basic safety precautions should always be followed, including: DanGer: •...
  • Page 8 on the grounding lug, inside the equipment compartment on the equipment box. • A grounding wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.
  • Page 9 J-400 Series warnInG: • Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, if pregnant or possibly pregnant, consult your physician before using a spa. • Pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
  • Page 10 9. CauTIOn: TO DeCrease rIsK OF PrODuCT DamaGe. • Maintain water chemistry in accordance with manufacturer’s instructions. • Proper chemical maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components. 10. nOTe: This spa is not intended nor designed to be used in a commercial or public application.
  • Page 11: Entrapment Risk

    J-400 Series entrapment risk The Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drain and/or suction fittings causing death, drowning, or serious injury (see diagram below). This spa was manufactured to meet the standards and specifica- tions outlined in the “Virginia Graeme Baker Pool and Spa Safety Act”...
  • Page 12: Hyperthermia

    For additional or replacement Warning Signs please contact your local Jacuzzi dealer and reference item number #6530-082. rIsK OF seVere InJurY Or DrOwnInG! rIsK OF seVere InJurY Or DrOwnInG! rIsK OF seVere InJurY Or DrOwnInG! danger of drowning.
  • Page 13: Important Csa Safety Instructions (Canada Only)

    J-400 Series Important Csa safety instructions (Canada only) When using this electrical equipment, basic safety precautions should always be followed, including the following: 1. reaD anD FOllOw all InsTruCTIOns. 2. A green colored terminal or a terminal marked G, Gr, Ground, Grounding or the or compartment.
  • Page 14: Outdoor Location

    warnInG: or other platforms not specifically tied into main structural support, consult a professional structural engineer with experience in this type of application. The spa must be installed in such a manner as to provide drainage away from it. Placing the spa in a depression without provisions for proper drainage could allow rain, overflow and other casual water to flood the equipment and create a wet condition in which it would sit in.
  • Page 15: Indoor Location

    J-400 Series Indoor location For indoor installations many factors need to be considered before installing a spa indoors. • Proper Foundation: considering a foundation that will adequately support the spa the entire time it is in place. Proper support is critical especially if the spa is to rest on a second story or higher.
  • Page 16: General Electrical Safety Instructions

    Please contact your local Jacuzzi dealer or local building department should you have any questions regarding your installation. Proper grounding is extremely important. Jacuzzi spas are equipped with a current collector system. A pressure wire connector is provided on the...
  • Page 17 J-400 Series • All wiring must be copper to ensure proper connections. aluminum wire. • When using wire larger than #6 (10 mm²), add a junction box near the spa and reduce to short lengths of #8 (8.4 mm²) wire to connect to the spa.
  • Page 18 Note: Pump Locations Vary by Model Control Box Power Supply Entrance(s) Jet Pump #1 Heater Spa Drain Valve Pump Drain Plugs(s) Terminal Block Bonding Lug Grounding Terminal Figure a equipment area Jets Pump #2 Filter/Circulation Pump Optional CD Ozonator (Purchase Separately) 10.
  • Page 19: 7.0 Power Requirements

    240V models: 240 VAC, 3-Wire Connection 60 Hz 7.0 Power requirements Jacuzzi® spas are designed to provide optimum performance and flexibility of use when connected to their maximum electrical service. They are configured at the factory. The most common electrical connections are listed below: •...
  • Page 20: 8.0 Spa Fill Up Procedure

    Clear all debris from the spa. (Although the spa shell has been polished at the factory, you may want to treat it with a specially formulated spa cleaner. Consult your authorized Jacuzzi dealer for additional information prior to filling spa.
  • Page 21 Turn on all jets(s) pumps when adding chemicals in step 5. 5. add start-up Chemicals Add the spa water chemicals as recommended by your authorized Jacuzzi spa dealer. See section titled “Water Quality Maintenance” (page 49) for general guidance. warnInG: Never leave chemicals opened and accessible to anyone.
  • Page 22 7. set spa To Heat To warm spa water to a comfortable temperature, follow these steps: • The LCD display on the control panel displays the actual temperature of the spa water. Press either the COOler or warmer temperature for 5 seconds. If you want the water to heat to a different temperature, simply press COOler seconds.
  • Page 23 J-400 Series 1. Add 2.5 ounces of sodium dichlor for every 100 gallons of water. Refer to the table below for approximate water fill volume by model. CauTIOn: rIsK OF PersOnal InJurY Or sPa DamaGe! Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemical may damage components within your hot tub, burn or irritate your skin, create a rash, and void the manufacturer warranty for your spa.
  • Page 24 “hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. You may fill entirely with hard water if you use a special water additive available from your Jacuzzi dealer. 5. Consult your authorized Jacuzzi dealer for chemical...
  • Page 25: 9.0 Control Functions

    J-400 Series 9.0 Control Functions Control Panel a. select Button: Filter cycle programming features. Pressing the select button also allows you to turn on/off the circulation pump, when it is in an off state. If the circulation pump was turned on automatically, it cannot be manually turned off. B.
  • Page 26: Lcd Display

    lCD Display = lock: Indicates panel, set temperature, or filter cycle programming is locked. = Heat: Indicates heater is on. = Ozone: Indicates optional CD ozonator is on. = adjust Filter Cycle: Indicates filter cycle programming feature is accessed. = Filter Cycle number: Indicates which programmed filter cycle is running.
  • Page 27: J-480 Spa Features

    J-400 Series J-480 spa Features Control Panel Waterfall Control Valve Air Control Valves (4 ea.) Introduce Air to Specified Jet Groups (Page Optional Audio System Speakers (4 ea.) Adjustable Pillows (4 ea.) Lighted Cup Holders ( Massage Selectors (2 ea.) Controls Specified Jet Groups (Page 29) Waterfalls (2 ea.) FX Jets (4 ea.) And FX2 Jets (2 ea.)
  • Page 28: J-470 Spa Features

    J-470 spa Features Control Panel Waterfall Control Valve Air Control Valves (4 ea.) Introduce Air to Specified Jet Groups (Page Optional Audio System Speakers (4 ea.) Adjustable Pillows (4 ea.) Lighted Cup Holders ( Massage Selectors (2 ea.) Controls Specified Jet Groups (Page 31). Waterfalls (2 ea.) FX Jets (6 ea.) ProClear™...
  • Page 29: J-465 Spa Features

    J-400 Series J-465 spa Features Control Panel Waterfall Control Valve Air Control Valves (3 ea.) Introduce Air to Specified Jet Groups (Page Optional Audio System Speakers (4 ea.) Adjustable Pillows (4 ea.) Lighted Cup Holders ( Massage Selectors (1 ea.) Controls Specified Jet Groups (Page 33).
  • Page 30: J-460 Spa Features

    J-460 spa Features Control Panel Waterfall Control Valve Air Control Valves (4 ea.) Introduce Air to Specified Jet Groups (Page Optional Audio System Speakers (4 ea.) Adjustable Pillows (4 ea.) Lighted Cup Holders ( Massage Selector (1 ea.) Controls Specified Jet Groups (Page 35). Waterfall FX Jets (18 ea.) FX2 Jets (5 ea.)
  • Page 31: Operating Instructions

    (pages 22-25). These controls let you operate many of the special functions of your Jacuzzi spa. By familiarizing yourself with the following information, you will be able to gain the full benefit from using your spa .
  • Page 32: Light Mode Button

    10.6 light mode Button This button offers 4 light modes for your enjoyment. Press this button to select your favorite lighting effect as follows: Press Displays hundreds of colors in 5 second intervals. Once Press Displays hundreds of colors in 20 seconds intervals. Again Press Selects or “freezes”...
  • Page 33: Watercolour™ Waterfall Control

    10.12 Optional J-1000™ Jacuzzi audio system Jacuzzi models equipped with the optional audio system offer enhanced hot tub enjoyment by offering an integrated state-of-the-art audio system. These models include an integrated...
  • Page 34: J-480 Massage/Waterfall Selector Diagram

    10.13 J-480 massage/waterfall selector Diagram Massage Selectors (1-2) • Massage selector 1 diverts pump 2 output between jets groups 1a-1b. • Massage selector 2 diverts pump 1 output between jet groups 2a-2b. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfalls. Massage Selector (4) • Massage selector 4 controls pump 1 output to footwell IX Jet. Jets Without Massage Selector Controls (5) • Jets 5 are always on when jets pump 2 is running. Spa operation subject to change without notice. J-400 Series Page 29...
  • Page 35: J-480 Air Controls Diagram

    J-400 Series 10.14 J-480 air Controls Diagram air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet draws air at all times when jets pump 1 is running. This jet has no air control. Page 30 Spa operation subject to change without notice.
  • Page 36: J-470 Massage/Waterfall Selector Diagram

    10.15 J-470 massage/waterfall selector Diagram Massage Selectors (1-2) • Massage selector 1 diverts pump 2 output between jets groups 1a-1b. • Massage selector 2 diverts pump 1 output between jet groups 2a-2b. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfalls. Massage Selector (4) • Massage selector 4 controls pump 1 output to footwell IX Jet. Jets Without Massage Selector Controls (5) • Jets 5 are always on when jets pump 2 is running. Spa operation subject to change without notice. J-400 Series Page 31...
  • Page 37: J-470 Air Controls Diagram

    J-400 Series 10.16 J-470 air Controls Diagram air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet draws air at all times when jets pump 1 is running. This jet has no air control. Page 32 Spa operation subject to change without notice.
  • Page 38: J-465 Massage/Waterfall Selector Diagram

    J-400 Series 10.17 J-465 massage/waterfall selector Diagram Spa operation subject to change without notice. Massage Selectors (1) • Massage selector 1 diverts pump 1 output between jets groups 1a-1b. Massage Selector (2) • Massage selector 2 controls pump 1 output to footwell IX Jet. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfall. Jets Without Massage Selector Controls (4) • Jets 4 are always on when jets pump 2 is running. Page 33...
  • Page 39: J-465 Air Controls Diagram

    J-400 Series 10.18 J-465 air Controls Diagram Spa operation subject to change without notice. air Controls Operation • Rotate air controls 1-3 to add air to designated jet groups. Page 34...
  • Page 40: J-460 Massage/Waterfall Selector Diagram

    10.19 J-460 massage/waterfall selector Diagram Massage Selector (1) • Massage selector 1 diverts pump 1 output between jets groups 1a-1b. Massage Selector (2) • Massage selector 2 controls pump 1 output to footwell IX Jet. Waterfall Selector (3) • Waterfall selector 3 controls circulation pump output to waterfall. Jets Without Massage Selector Controls (4) • Jets 4 are always on when jets pump 2 is running. Spa operation subject to change without notice. J-400 Series Page 35...
  • Page 41: J-460 Air Controls Diagram

    J-400 Series 10.20 J-460 air Controls Diagram air Controls Operation • Rotate air controls 1-4 to add air to designated jet groups. • Center footwell IX Jet (5) draws air at all times when jets pump 1 is running. This jet has no air control. Page 36 Spa operation subject to change without notice.
  • Page 42: Heating Modes

    11.0 Heating modes The control system in your spa activates a programmable “standard” or “economy” mode which effects when the heater operates. Refer to sections 11.1 and 11.2 below for additional information. 11.1 standard mode (Factory Default) Standard mode is typically selected by customers in cold climates where heat up times are extended due to lower ambient temperatures.
  • Page 43: Programming Instructions

    J-400 Series 12.0 Programming Instructions 12.1 Programming Filter/Circulation Pump run Time The Sentry control system allows you to easily adjust two separate aspects of filter/circulation pump operation: 1. The time of day (start time) the filter/circulation pump turns on. 2. The length of time (duration) the filter/circulation pump operates. The factory default start time is 12:00AM (Midnight).
  • Page 44 When in a Summer Logic condition is active (see note below), the filter/ circulation pump will turn on for all programmed filter cycles. summer logic: In warm weather, the water temperature in the spa may exceed the set temperature. This condition may occur due to heat transference from the filter/circulation pump and jets pumps.
  • Page 45: Adjusting Time Of Day

    J-400 Series When a programmed filter/heating cycle activates, the LCD screen displays the following message: At any time, you may check the programming of any aspect of any filter/ heating cycle by first pressing CYCle the menu by pressing either CYCle programming is changed only by pressing warmer buttons during this process.
  • Page 46: Locking Filter Cycles

    12.5 locking Filter Cycles You may keep all filter cycle programs from being inadvertently altered by electronically “locking” them. • To Lock All Filter Cycles: Press CYCle within 30 seconds, press DIsPlaY warmer buttons within five seconds each. A padlock symbol will appear on the screen.
  • Page 47 J-400 Series Programming Instructions 1. Press the CYCle indicating the “Change Filter” display program has been accessed. 2. Press seleCT programmed duration or to view days elapsed since last filter cleaning interval. 3. Press warmer setting as follows: 0 - 10 - 20 - 30 - 40 - 50 - 60 - 70 - 80 - 90 - 100 - 110 - 120 - OFF note: Selecting 0 in step 3 forces the change filter reminder icon to remain on indefinitely.
  • Page 48: Spa Maintenance

    13.0 spa maintenance Proper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Jacuzzi dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this. DanGer: rIsK OF seVere InJurY Or DrOwnInG BY enTraPmenT! •...
  • Page 49 J-400 Series To ensure optimum performance, the 24-hour ProClear™ II skimming filter cartridge (A) must be cleaned every three months and replaced once a year. The secondary ProClear™ Plus polishing filter bag (B) should be emptied weekly and replaced every 3 months. The ProClear™ II filter cartridge (C) must be cleaned every three months and replaced once a year.
  • Page 50: Draining And Refilling

    When replacing the filter cartridge, make sure you remove the center cap and chemical dispenser for use with the new cartridge. Replacement filter cartridges may be purchased from your authorized Jacuzzi dealer. 13.2 Draining and refilling About every 3 to 6 months, you will want to replace the spa’s water.
  • Page 51: Cleaning The Spa Interior

    13.6 maintaining the Cover Using the Jacuzzi insulating spa cover anytime the spa is not in use will significantly reduce your operating costs, heat-up time, and maintenance requirements. To prolong the life of the cover, handle it with care and clean it regularly using mild soap and water.
  • Page 52: Winterizing

    13.7 winterizing Your Jacuzzi spa is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the electrical supply to the spa has not been interrupted. In extreme, bitter cold weather (less than -20°F) verify standard mode is set for 24-hour...
  • Page 53: Restarting Your Spa In Cold Weather

    J-400 Series Consult your Jacuzzi dealer if you have any questions regarding winter use or winterizing. 13.8 restarting Your spa in Cold weather If you want to start up your spa after it has sat empty for a time in freezing temperatures, be aware that the water remaining in certain sections of the piping may still be frozen.
  • Page 54: Water Quality Maintenance

    Your authorized Jacuzzi dealer can advise you on the use of these additives. FaIlure TO maInTaIn waTer QualITY...
  • Page 55: Other Additives

    Your Authorized Jacuzzi dealer can advise you on the use of these additives. 14.4 Ozone water maintenance system This system is optional on North American models and standard equipment on export 50 Hz modes.
  • Page 56: Troubleshooting - Display Messages

    15.0 Troubleshooting - Display messages There are a number of unique functions designed into your Jacuzzi spa to protect it from damage and/or to aid in troubleshooting. Following is a listing of all the possible messages along with their meanings:...
  • Page 57 J-400 Series FREEZE PROTECTION A potential freeze condition has been detected. No action is required. Jets pump(s) operate until the spa is out of danger. It is possible to manually turn off pump 1 and pump 2, but if after 2 hours ICE is still detected, pumps will automatically turn back on.
  • Page 58: Troubleshooting - Procedures

    16.0 Troubleshooting - Procedures In the unlikely event your spa is not working the way you believe it should, please first review all the installation and operating instructions in this manual and check the message on the panel display; second, if you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions.
  • Page 59 Your input as a Jacuzzi spa owner is a cherished part of this process. If you have any comments or suggestions, or if you wish to be informed on any new products for your spa, please write to us.
  • Page 60: North American 60 Hz J-460/J-465/J-470/J-480 Wiring Diagram

    J-400 Series 17.0 north american 60 Hz J-460/J-465/J-470/J-480 wiring Diagram JP19 JP19 Page 55...
  • Page 61: Export 50 Hz J-460/J-465/J-470/J-480 Wiring Diagram

    J-400 Series 18.0 export 50 Hz J-460/J-465/J-470/J-480 wiring Diagram JP19 JP19 Page 56...
  • Page 62: Typical Spa Wiring Diagrams A-B (North American 60Hz Models Only)

    19.0 Typical spa wiring Diagrams a-B (north american 60Hz models Only) 2-Pole Circuit Breaker with 2-Wire Grounded Load Connection (3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground) 240 VAC White (N) Black (L1) Red (L2) Main Service Panel with GFCI Ground Main Panel with Secondary GFCI Shut-Off Box Using a 2-Pole GFCI Breaker with 2-Wire Grounded Connection...
  • Page 63: Optional Jacuzzi J-1000 Audio System™ Stereo System Features

    J-400 Series 20.0 Optional Jacuzzi J-1000 audio system™ stereo system Features 20.1 sound system Controls 1. Power On/Off Button 2. Tune/Seek Up/Down Button 3. Volume Up/Down Button 4. Mode Button 5. SEL/EQ Button 6. AS/PS Button 7. MUTE Button 8. BAND/RPT Button 9.
  • Page 64: Sound System Operation

    20.2 sound system Operation 1. Power On and Off Press power button (1) once to turn on stereo system. Press a second time to turn off. 2. adjusting Volume Press VOL Up/Down button (3) to increase or decrease volume. Current volume setting is briefly displayed (0 to 45).
  • Page 65 J-400 Series 8. adjusting Fader level Press EQ button (5) repeatedly until display reads “FADER.” Press VOL Up/ Down button (3) to choose desired set- ting. A display of “FADER F-R” indicates center, R01 to 15 indicates rear fade, F01 to 15 indicates front fade. note: Unit returns to volume mode if volume control is not operated for 3 seconds.
  • Page 66: J-1000™ Audio System Radio Operation

    12. Open/Close Front Panel Press firmly on the release button (15), then open front panel (16) by gently lifting upward on bottom edge. To close front panel, gently flip panel down, then press firmly on panel directly above release button (15) until you hear an audible “click”.
  • Page 67: J-1000™ Audio System Cd Player Operation

    J-400 Series 5. accessing Preset stations Press and hold ENT/SH button (9) until display reads “SHIFT”. Repeatedly press TUN up or down button (2) to choose preset 1-6, then press ENT/SH button (9) to confirm selection. 20.4 J-1000™ audio system CD Player Operation 1.
  • Page 68: J-1000™ Audio System Usb & Nand Operation

    Press a second time to deactivate or press RDM button to cancel RPT function. searching File or Folder in mP3/wma CD • To Search File in CDP (MP3/WMA) mode: Press AS/PS button (6) to enter track searching mode. Then press the VOL up/down button (3) to scroll through available tracks.
  • Page 69 J-400 Series 2. Copying music Files from usB to nanD (internal memory) In USB mode, press and hold SEL button (5) for about 2 seconds until “ONE COPY” displays on LCD (17), then press VOL up or down button (3) to choose ONE or ALL.
  • Page 70: J-1000™ Audio System Ipod Operation

    20.6 J-1000™ audio system iPod Operation 1. Play iPod Open front panel (16) and plug a iPod into the iPod Docking Station (12) as shown. Refer to step 12 (page 61) for details. The iPod will begin to play automatically. Close front panel. The “iPod” symbol will display to indicate a iPod is connected.
  • Page 71: Docking Your Ipod Music Player

    J-400 Series 20.7 Docking your iPod music Player 1. Docking Your iPod The Docking Station for iPod is compatible with all dockable Apple iPod models. To Install an Apple iPod: A. Open Docking Station door (A) as outlined in step 12 (page 61). B.
  • Page 72: Generic Mp3 Player Operation

    20.8 Generic mP3 Player Operation 1. Connecting Your mP3 Player A. The Audio unit is equipped with an auxiliary audio input jack, that allows the user to listen to external source, such as an MP3 Player. 2. setting up The mP3 Player for use A.
  • Page 73: J-1000™ Audio System Stereo Specifications

    J-400 Series 2. Fogged CDs and lens This condition may occur when it’s cold. Wipe fogged CDs with a soft cloth. Fogged optical components inside the unit will return to normal operation after an hour in a heated environment. 20.10 J-1000™...
  • Page 74: Standard Wireless Remote Control

    20.11 standard wireless remote Control (Included With Optional J-1000 Sound System) • Usable range 15' (5m) • Never leave the remote under the spa cover for any reason. • Battery Replacement: Use Coin Type, CR2025 or equivalent. wireless remote Control Command summary Button Operation Power Button: On/Off.
  • Page 75 J-400 Series Button Operation Auto Button: Scans through preset radio Auto stations. Audio Button: Selects treble, bass, fader or balance, Audio audio settings. Band Button: Selects AM or FM Band band. Volume Buttons: Zone 1 buttons Zone 1 Zone 2 are used to adjust volume levels.
  • Page 76: Wireless Remote Battery Replacement Procedure

    20.12 wireless remote Battery replacement Procedure 1. Start by removing the rubber cover to the remote (Figure A). 2. Turn the remote unit over and locate the battery door (Figure B). 3. Rotate the battery door, with a coin, counterclockwise until the dot aligns with the Open arrow (Figure C).
  • Page 77 J-400 Series Serial Number: Model Name: Dealer Name: Notes: ___________________________________ _________________________________________ _________________________________________ _________________________________________ Page 72 ___________________________ ___________________________ ___________________________...

This manual is also suitable for:

J-460J-465J-470J-480

Table of Contents