Reservoir Drain Pump
Remove the ice from the storage bin prior to
removing the recirculation pump.
Note: Pump operates on 12VAC and has a
resistance of 3.8Ω.
To remove the reservoir drain pump:
1.
Unscrew the drain cap from the reservoir, drain
the water, and replace the cap tightly.
2.
Remove the recirculating pump cover hex-head
screw.
Drain Cap
3.
Disconnect the reservoir drain pump electrical
connection.
4.
Remove the pump-retaining Phillips-head screw
and bracket.
5.
Rotate the pump 1/4 turn and pull it down and
out of the reservoir.
Disconnect

Condenser Fan Motor

To remove the condenser fan motor:
1.
Disconnect the water and drain lines from
the icemaker and remove the unit from its
installation.
2.
Remove the 4 hex-head screws from the front
panel and remove the panel.
3.
Remove the two 5/16-in. screws from the front
of the cabinet.
4.
Remove 2 hex-head screws from the measured
fi ll water valve bracket.
5.
Allow the valve to drop down out of the way.
Measured Fill Water Valve