Download Print this page

Section Five Fault-Finding - Heatrae Sadia DART 2005 Installation And User Instructions Manual

Advertisement

21/03/2011
4.33 Press the push-buttons in turn to check that their mechanism operates smoothly.
Page 12
Testing:
Once you have finished installing your shower, carry out the following tests to ensure that you have followed our
installation instructions correctly and that your shower is functioning as it should.
4.34 Secure the handset on the riser rail where it can spray safely. Press the 'Low' button.
Turn the water control knob fully clockwise.
4.35 Turn on the isolating valve (if applicable).
4.36 Slowly turn the control knob anti-clockwise. There may be gurgling noises as water fills the heater can, then
water will start to flow. Press the 'High' button.
4.37 Turn the water control knob further anti-clockwise, until the 'Power On' light illumunates. The elements are now
heating.
4.38 Adjust the water control knob to give the desired temperature. Turn clockwise for warmer, anti-clockwise for
cooler. Allow a few seconds after each adjustment for the temperature to stabilise. The high/low power selector push
buttons allows you to choose the power used by the heater. The low setting which uses less electricity can be used
in the summer to decrease the spray temperature, when the incoming water temperature is likely to be higher. A cold
shower can be obtained by leaving the isolating switch off and adjusting the flow rate using the water control knob.
Figure 4.54 External features of shower
Page 13

SECTION FIVE Fault-Finding

In the unlikely event of a problem, consult the trouble-shooting chart below.
For your particular symptom follow the suggested remedies in the order given.
If you are unable to remedy the problem, CONTACT YOUR INSTALLER IN THE FIRST INSTANCE . Do not attempt
any electrical or plumbing work unless you are competent to do so.
partsarena.co.uk/baxi/.../I47-2835.htm
www.partsarena.co.uk/baxi/System/DA...
13/16

Advertisement

loading