ADJUSTMENT OF THE OVEN BURNER MINIMUM

This needs to be done only for the oven burner (the broil is a fi xed capacity) by acting
on the thermostat in the following way:
Turn on the burner by setting the thermostat knob on position "8" (maximum).
Remove the knob and unscrew the by-pass screw "G" (fi g. 2.18) about three times by
passing a small fl at screwdriver (Ø 3 mm blade, 100 mm length) through the panel
opening.
Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob
to position "1" (minimum) to operate the thermostat by-pass.
After having removed the knob again and being very careful not to turn the tap rod,
slowly screw the by-pass screws "G" (fi g. 2.18) until you obtain a fl ame of 3-4 mm in
height. The fl ame should not go out even when passing suddenly from maximum to
minimum fl ame.
N.B. For LP/PROPANE gas the by-pass screw must be fi xed thoroughly.
After regulation repeat the operations indicated in paragraph "2. PRESSURE REGULA-
TOR" at page 12 and 15.
If the range has been disconnected and then connected again to the gas supply line repe-
at the operations indicated in paragraph "5. LEAK TESTING" at page 15.
IMPORTANT:
After conversion to LP/PROPANE gas has been carried out affi x near the data plate
the conversion label supplied and also affi x a conversion label at page 3 of this in-
struction manual.
After conversion back to the original gas (NATURAL GAS) has been carried out re-
move, near the data plate and at page 3 of this instruction manual, the LP/PROPANE
conversion labels. Save the labels removed for future use.
Fig. 2.18