Clearances To Combustibles - Quadra-Fire YOSEMITE-MBK Owner's Manual

Non-catalytic, front/side load, wood heater installation and operation
Hide thumbs Also See for YOSEMITE-MBK:
Table of Contents

Advertisement

Yosemite Wood Stove
B. Clearances To Combustibles (UL And ULC)
B
A
C2
C1
D2
D1
Fuel Door
side
Non-fuel
door side
Alcove
IF SIDE FUEL LOADING DOOR IS NOT USED:
• It must remain in the locked position at all times
• Use clearances for non-fuel door side for both sides
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
TOP VENT VERTICAL
Single Wall-USA
Single Wall-Canada
Double Wall-USA
Double Wall-Canada 10.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
Single Wall-Canada
Double Wall-USA
Double Wall-Canada 11.5(330) 8(203)
90
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
O
Single Wall-USA
Single Wall-Canada
Double Wall-USA
Double Wall-Canada
ALCOVE -
Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)
Double Wall-USA
Double Wall-Canada 11.5(292) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL:
listed double wall air insulated connector pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home
must be equipped with a spark arrestor). Additional specifications include a MAXIMUM 10" (254mm) MANTEL WIDTH and the following
clearances. Accessory Horizontal Heat Shield, Part HTSHLD-7006, is required for rear vent installations.
Double Wall-USA
Double Wall-Canada
*NFPA MINIMUM CLEARANCE - NOT TESTED
Page 10
E1
Non-fuel
F1
door side
E2
Fuel door
side
Vertical
A
B
C1
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A
12.5(316) 9(229) 19.5(495) 27.5(699) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406)
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
11.5(330) 8(203)
19.5(495) 25.5(648) 10(254) 16(406)
19.5(495) 27.5(699) 10(254) 18(457)
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
11(279) 7.5(191) 19.5(495) 25.5(648) 10(254) 16(406) N/A
11(279) 7.5(191) 19.5(495) 27.5(699) 10(254) 18(457) N/A
Front Door
Side Door-USA
Side Door-Canada
11.5(292) 8(203) 19.5(495) 25.5(648) 10(254) 16(406) N/A
N/A
4(102) 19.5(495) 25.5(658) 10(254) 16(406) N/A
N/A
4(102) 19.5(495) 27.5(699) 10(254) 18(457) N/A
Max Mantel Depth
10" (254mm)
F2
Ceiling
Horizontal
C2
D1
D2
E1
N/A
N/A
N/A
Max Depth
Min Width
48(1219)
44(1118)
48(1219)
56(1422)
48(1219)
60(1524)
USA or Canada - Single or Double Wall Pipe: 21(533) mantel
7004-187I
G
G*
Mantel
Vertical then Horizontal
E2
F1
F2
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
59(1499) N/A
N/A
N/A
N/A
59(1499) N/A
N/A
N/A
N/A
59(1499) N/A
N/A
N/A
N/A
59(1499) N/A
Min Height
54(1372)
54(1372)
54(1372)
N/A
N/A
N/A
42(1067) N/A
N/A
N/A
N/A
42(1067) N/A
Six inch (6") (152mm) diameter
N/A 30(762) ceiling N/A
N/A
N/A
N/A 30(762) ceiling N/A
N/A
N/A
R
H
G
Ceiling
G
H
December 20, 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yosemite-pmh

Table of Contents