Installing Chimney Components - Quadra-Fire YOSEMITE-MBK Owner's Manual

Non-catalytic, front/side load, wood heater installation and operation
Hide thumbs Also See for YOSEMITE-MBK:
Table of Contents

Advertisement

Masonry Chimney Liner (Cont'd)
Wood Stud 2 in.
(51mm)
Clearance from
chimney wall
Header
Fireclay liner 5/8 in.
(16mm) Minimum
or Equivalent.
Sill support
Thimble Assembly:
12 in. (305mm) of
brick separation
between clay liner
and combustibles.
Figure 19.1
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner's information manual provided with this appli-
ance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
Horizontal Flue Heat Shield, Accessory Part
HTSHLD-7006 is required for rear vent instal-
lations.
Optional Fire Screen, part SCR-7006, can only
be used in full vertical installations.
December 20, 2011
R
Fireclay liner 5/8 in.
(16mm) Minimum
or Equivalent.
C. Installing Chimney Components
Chimney Connector
Single wall connector or stove pipe.
This must be at least 24 gauge mild steel or 26 gauge blue
steel. The sections must be attached to the appliance and
to each other with the crimped (male) end pointing toward
the stove. All joints, including the connection at the flue
collar, should be secured with 3 sheet metal screws. Make
sure to follow the minimum clearances to combustibles.
Where passage through the wall, or partition of combustible
construction is desired in Canada, the installation shall
conform to CAN/CSA-B365.
Factory-built listed chimney connector (vented).
A listed connector (vented) must be used when installing
this unit in a mobile home. The listed connectors must
conform to each other to ensure a proper fit and seal.
Figure 19.2 Chimney Connector (Stove Pipe)
Fire Risk.
Follow Chimney Connector Manufacturer's
Instructions for Proper Installation.
ONLY use connector:
Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
Attic or roof space
Closet or similar concealed space
Floor or ceiling
Maintain minimum clearances to combustibles
7004-187I
Yosemite Wood Stove
Crimped
Flue Gas
End
Direction
Toward
Stove
Secure pipe sections with a
minimum of 3 screws
WARNING
Page 19