Correct Baffle & Blanket Placement - Quadra-Fire 31I-ACC Owner's Manual

Advanced combustion control (acc) wood insert installation and operation
Hide thumbs Also See for 31I-ACC:
Table of Contents

Advertisement

3100-I ACC Wood Insert
J. Correct Baffle & Blanket Placement
WARNING
Fire Risk
Firebox damage due to improper baffle place-
ment is not covered by warranty. Operate the
wood burning appliance with the baffle in the
correct position only.
Not doing so could result in:
• Reduced efficiency
• Overheating the chimney
• Overheating the rear of the firebox
• Poor performance
Ensure correct baffle placement and replace baffle com-
ponents if damaged or missing.
CORRECT POSITION
Ceramic Blanket
Baffle Board
Ceramic Blanket and Baffle Board MUST be
in contact with the back of the firebox and
even with each other in the front.
Figure 12.1 - Correct Baffle and Blanket Positions
Page 12
Back of Firebox
Figure 12.2 - Incorrect Baffle and Blanket Positions
7044-140B
INCORRECT POSITIONS
Ceramic Blanket and Baffle Board are NOT
in contact with the back of the firebox.
Ceramic Blanket is NOT in contact with the
back of the firebox and NOT even with the
Baffle Board in the front.
Ceramic Blanket
Baffle Board
Ceramic Blanket is bunched up at the back
of the firebox and NOT even with the Baffle
Board in the front.
R
Back of Firebox
February 10, 2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

3100-i acc

Table of Contents