Huato S300-E Operation Manual

Wireless data logger

Advertisement

Operation manual for Wireless Data Logger
(Version 1.00)
HUATO ELECTRONIC(SHENZHEN)CO., LTD
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S300-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Huato S300-E

  • Page 1 Operation manual for Wireless Data Logger (Version 1.00) HUATO ELECTRONIC(SHENZHEN)CO., LTD...
  • Page 2: Table Of Contents

    CONTENTS CHAPTER 1 BRIEF INTRODUCTIONS FOR TOMONITOR WIRELESS SYSTEM......1 S300-E W ) ............... 2 IRELESS TATION TRANSMISSION RELAY ..........................3 ETWORK OPOLOGY .......................... 4 TIME ONITORING : ............................ 5 EATURES 1.1.1 Technical Parameters for Wireless Base Station ..............5 1.1.2 Technical Parameters for Wireless Repeater.................
  • Page 3: Chapter 1 Brief Introductions For Tomonitor Wireless System

    Introduction of HUATO Wireless Temperature and Humidity Solution Chapter 1 Brief Introductions for ToMonitor Wireless System Wireless temperature & humidity data logger is a new generation of HUATO (SHENZHEN) COMPANY, it uses Zigbee (2.4G) network; Zigbee is a kind of short distance two-way wireless communication technology which enjoys low complexity, low consumption, low rate and low cost.
  • Page 4: S300-E Wireless Base Station (Transmission Relay)

    Introduction of HUATO Wireless Temperature and Humidity Solution S300-E Wireless Base Station (transmission relay) Wireless transmission rate: 115200 BPS. Wireless temperature humidity data logger terminal units available: 32 units. Frequency number supported: 15 Bands Display:Dual display. The first line shows the packets count received; the second line shows the last five numbers of the serial No of the last packets data logger.
  • Page 5: Network Topology

    Operation manual for Wireless Data Logger Network Topology In the project, there are lots of monitoring stations. Considering wireless signal and reliability problems, we adopt LAN and wireless equipment hybrid networking. ToMonitor Software use TCP/IP networking protocol to monitor each transmission relay (station), which collect the wireless list data respectively and real-timely send to ToMonitor server software via internal LAN.
  • Page 6: Real-Time Monitoring

    Operation manual for Wireless Data Logger (server ToMonitor monitoring system includes three parts: user layer (office/ Internet), control layer room) and equipment room (warehouse and exhibition hall). ToMonitor interior system is quite easy to manage; full automatic control and very accurate so that clients can save manpower and material recourses and fully satisfy the temperature humidity environment monitoring requirements.
  • Page 7: Features

    Operation manual for Wireless Data Logger Features: 1.1.1 Technical Parameters for Wireless Base Station Wireless transmission rate: 115200BPS Available wireless logger terminal number: 32 sets Dual display, the first line shows the accumulated number of the received data packets; the second displays the last serial five numbers of the logger. Internal (2.4G) wireless antenna.
  • Page 8: Model List

    Operation manual for Wireless Data Logger 1.3 Model List Temperature Humidity Model Sensor Type Remark Accuracy Accuracy 3.6V Li battery*2 No port for external Temperature +humidity, -20~70℃ ±0.3℃/±2%RH S380-WS internal power 0~100%RH LCD dual display 3.6V Li battery*2 Temperature +humidity, -20~70℃...
  • Page 9: Brief Introduction For Wireless Base Station

    Operation manual for Wireless Data Logger 1.4 Brief Introduction for Wireless Base Station 1.4.1 Wireless Base Station Interface LCD Display Ethernet Interface Lock Reset ON/OFF Hanger DC Interface 1.4.2 Introduction for LCD Display of Wireless Base Station Logging status DC outside power symbol Display wireless logger serial number Time display area Battery power indication...
  • Page 10: Brief Introduction For Wireless Repeater

    Operation manual for Wireless Data Logger 1.5 Brief Introduction for Wireless Repeater 1.5.1 Wireless repeater interface LCD display Wall-mounted back cover LED indication Back cover screw-fixed position USB and DC power interface 1.5.2 LCD display symbols introduction for Wireless repeater Power symbol Month and Date display area Signal symbol...
  • Page 11: Wireless Temperature & Humidity Data Logger (S380-Ws)

    Operation manual for Wireless Data Logger 1.6 Wireless temperature & humidity data logger (S380-WS) 1.6.1 Wireless temperature humidity logger interface LCD display USB interface ON/OFF(Log) Wall-mounted back cover ON/OFF(Power) Power back cover 1.6.2 Introduction for LCD display symbols of Wireless temperature humidity data logger Power symbol DC power symbol Signal symbol...
  • Page 12: Install Battery

    Operation manual for Wireless Data Logger 1.6.3 Install battery Take out the back cover as the indication symbol , and then install two 3.6v Lithium batteries 1.7 Wireless temperature & humidity data logger with LCD display. 1.7.1 Wireless temperature humidity logging interface LCD display Wall-mounted back cover LCD indicator...
  • Page 13: Introduction For Lcd Display Symbols Of Wireless Temperature Humidity Logger

    Operation manual for Wireless Data Logger 1.7.2 Introduction for LCD display symbols of Wireless temperature humidity logger Power symbol DC power symbol Signal symbol Auto logging symbol Selectable ℃/℉ symbol Wireless symbol ℃/℉ display Humidity symbol RH display 1.8 Wireless temperature & humidity data logger without LCD display Wall-mounted back cover LED indicator USB and DC power interface...
  • Page 14: Install Battery

    Operation manual for Wireless Data Logger 1.9 Install battery Loosen the screw cover with a screwdriver, then install four 3.6v lithium batteries as the battery cassette indication. --------P.12--------...
  • Page 15: Chapter 2 Instructions For Tomonitor Software Operation

    (1) Install ZNetCom software. The installation file is ZNetCom2.59_Setup.exe. Click the file, then choose language as English. (2) Connect the S300-E Base to the lan-switch or router. (3) Run ZNetCom, and then click the button “Search”. One item is shown in the right list.
  • Page 16 Instructions for ToMonitor Software Operation (5) The following items need to be modified manually: (a) IP (b) Mask (c) Gateway (d) Target IP 1: The IP of the PC that the ToMonitor is running. (6) After modify the properties, input the password “88888”, and then click the button “Apply Change”...
  • Page 17 Instructions for ToMonitor Software Operation 2.2 Configure ODBC. (1) In the control Panel of the PC, then click Data Source (ODBC). (2) Click “Add” button in the User DSN, and choose “Driver do Microsoft Access”. (3) Input the Data Source Name as “S400W”. (4) Select the database to s400w.mdb in the installation directory.
  • Page 18 Instructions for ToMonitor Software Operation 2.3 Introduction for ToMonitor Software. After configure S300-E Base and ODBC, and then run ToMonitor software. (1) Login to the system. Click the button “Login”, and then input user name and password. The initial name and password are “admin”.
  • Page 19 Instructions for ToMonitor Software Operation (2) System configuration After Login in, and then click the button “System”. The DB Saving Interval means how long one record of the logger will be loaded into the DB. For example, two or more records was received in ten minutes, But only the first was loaded into the DB, and others were rejected.
  • Page 20 ToMonitor. The working time is 8 am to 6 pm in the working days. The others are in Off time. HUATO ELECTRONIC (SHENZHEN) CO., LTD. Address: F3 of Building 1, Taohuayuan Technological Innovation Zone, Xixiang Street, Baoan District,Shenzhen,China.

Table of Contents