Namur sensor (Specified for EX zones)
15.9
Motor data
Motor data Makro TZ (TZMb)
Identity code
Phase, protection
specification
S
3 ph, IP 55
L1
3 ph, II2GEEX‐
L2
3 ph, II2GEEX‐
P1
3 ph, II2GEEX‐
P2
3 ph, II2GEEX‐
R
3 ph, IP 55
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
blue
brown
Rated voltage
220-240 V/
380-420 V
250-280 V/
440-480 V
220-240 V/
eIIT3
380-420 V
220-240 V/
dIICT4
380-420 V
250-280 V/
eIIT3
440-480 V
250-280 V/
dIICT4
440-480 V
230 V/400 V
For safety reasons we recommend connecting to a pro‐
–
tective low voltage, e.g. in accordance with EN 60335-1
(SELV ).
The cable can be poled as required.
–
Polarity
-
+
The monitor / power supply must be able to evaluate the cur‐
rent variations to indicate a diaphragm rupture!
Mains supply fre‐
Rated output
quency
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
60 Hz
50/60 Hz
Technical data
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm
Remarks
0.75 kW
0.75 kW
0.75 kW
0.75 kW
with PTC, speed
control range 1:5
0.75 kW
0.75 kW
with PTC, speed
control range 1:5
1.5 kW
with PTC, speed
control range 1:20
with external fan
1 ph 230 V; 50/60
Hz
55