Accuracy; Reproducibility; Metering Precision - ProMinent TZ Operating Instructions Manual

Diaphragm metering pump
Table of Contents

Advertisement

Main pumps with motor 1800 rpm under
60 Hz operation
Type
Minimum pump capacity at maximum
back pressure
psi
120260
174
120340
174
120430
174
120510
174
120650
174
70430
100
70570
100
70720
100
70860
100
71070
100
40840
58
41100
58
41400
58
41670
58
42100
58
15.2

Accuracy

15.2.1

Reproducibility

15.2.2

Metering precision

Maximum
stroke rate
l/h
gph
Strokes/min
309
81.8
414
109.5
518
137
622
164.5
511
135
683
180
855
226
1028
272
1001
264
1339
354
1676
443
2014
532
* Material versions PPT, PCT, TTT / SST
The permissible priming pressure at the suction side is approximately 50%
of the max. permitted back pressure
With double head pumps, the maximum permissible back pressure
reduces from 101.5 to 80 psi or from 58 to 43.5 psi.
All figures refer to water at 20 °C.
The suction lift applies to filled suction line and filled liquid end - when
installed correctly.
The priming lift of 2 m applies for clean and moistened valves and a clear
outlet
Data
Reproducibility
* for measurements taken under constant conditions, minimum 30 %
stroke rate and water at 20 °C - when installed correctly, p< 1 bar
Data
Metering precision
Suction
Connector size
lift
m WS
86
4
115
4
144
4
173
4
4
86
3.5
115
3.5
144
3.5
173
3.5
3.5
86
3
115
3
144
3
173
3
3
Technical data
Shipping
weight*
G-DN
kg
1 1/2 - 25
46/54
1 1/2 - 25
46/54
1 1/2 - 25
46/54
1 1/2 - 25
46/54
1 1/2 - 25
46/54
2 - 32
50/64
2 - 32
50/64
2 - 32
50/64
2 - 32
50/64
2 - 32
50/64
2 1/4 - 40
56/80
2 1/4 - 40
56/80
2 1/4 - 40
56/80
2 1/4 - 40
56/80
2 1/4 - 40
56/80
Value Unit
±2 % *
Value Unit
±1 % *
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

TzmbMakro tzMakro tzmb

Table of Contents