A.1.2 Connecting the LCD monitor and control chassis
Before you connect LCD monitor, there are four connections between
the LCD monitor and the AWS-8259 chassis: These connectors are the
VGA, Keyboard, USB/Power/Indicator and optional RS-232 for touch
screen. Because the AWS-8259 integrates the power, indicator signal,
and USB into one cable, users do not need to connect another power
cord. In addition, please follow the steps.
Note: The max. distance between LCD monitor and chassis is 2 meter.
VGA cable
PS/2 cable
USB/Indicator/
Power cable

Figure A-2: Connecting the control chassis

APPENDIX A AWS-8259 Separate system setup