Advantech ARK-7060 User Manual

Advantech ARK-7060 User Manual

Embedded box pc

Advertisement

Quick Links

User Manual
ARK-7060
Embedded Box PC

Advertisement

Table of Contents
loading

Summary of Contents for Advantech ARK-7060

  • Page 1 User Manual ARK-7060 Embedded Box PC...
  • Page 2 This package contains a hard-copy user manual in Chinese for China CCC certifica- tion purposes. There is an English user manual included as a PDF file on the CD. Please disregard the Chinese hard copy user manual if the product is not to be sold and/or installed in China. ARK-7060 User Manual...
  • Page 3 No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. The information provided in this manual is intended to be accurate and reliable.
  • Page 4 Product Warranty (2 years) Advantech warrants the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products that have been repaired or altered by persons other than repair personnel authorized by Advantech, or products that have been subject to misuse, abuse, accident, or improper installation.
  • Page 5 Technical Support and Assistance Visit the Advantech website at www.advantech.com/support to obtain the latest product information. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before calling: –...
  • Page 6 (Up to 4) U4A1 1 x PCIx16 D-1715TER Note! Memory/Storage and operating system bundled by request. ARK-7060 Default SKU Option Items Optional Item for Default SKU Part Number Description 1702002600 Power cable 3-pin 183 cm (64.1 in), USA type 1702002605 Power cable 3-pin 183 cm (64.1 in), EU type...
  • Page 7 Use a power cord connected to a socket-outlet with a grounded connection. This product is intended to be supplied by a UL Listed power supply suitable for use at minimum Tma 50 °C (122 °F) whose output meets PS2 (or LPS), ES1(or ARK-7060 User Manual...
  • Page 8 SELV) and output is rated: 9-36Vdc, 16.65-4.16A. Please contact Advantech for further information. DISCLAIMER: These instructions are provided according to IEC 704-1 standards. Advantech disclaims all responsibility for the accuracy of any statements contained herein. Consignes de Sécurité Veuillez lire attentivement ces instructions de sécurité.
  • Page 9 PS2 (ou LPS), ES1 (ou SELV) et dont la sortie est nominale: 9-36Vdc, 16.65- 4.16A, si besoin d'aide supplémentaire, veuillez contacter Advantech pour plus d'informations. AVERTISSEMENT: Cet ensemble d'instructions est donné conformément à la norme CEI 704-1. Advantech décline toute responsabilité quant à l'exactitude des déclara- tions contenues dans ce. ARK-7060 User Manual...
  • Page 10 ARK-7060 User Manual...
  • Page 11: Table Of Contents

    1.3.1 Functional Specifications .............. 4 1.3.2 SUSI 4.2..................4 Mechanical Specifications................. 5 1.4.1 Dimensions ................... 5 Figure 1.1 ARK-7060 Mechanical Dimensions Diagram ..... 5 1.4.2 Weight................... 6 Power Requirements................. 6 1.5.1 System Power................6 Operating Environment Specifications ............6 1.6.1 Operating Temperature..............
  • Page 12 Socket Configuration ..............69 3.2.5 Server Management ..............81 3.2.6 Security..................87 3.2.7 Boot .................... 89 3.2.8 Save & Exit ................. 90 Appendix A Watchdog Timer Sample Code ..91 EC Watchdog Timer Sample Code ............92 ARK-7060 User Manual...
  • Page 13: Chapter 1 General Introduction

    Chapter General Introduction This chapter details background information on the ARK-7060 series.
  • Page 14: Introduction

    Multiple I/O and Storage Capabilities ARK-7060 offers 2 x GbE, 4 x USB 3.0, and 4 x COM ports. It also supports up to 4 x 2.5” SATA III hard drive bays and delivers high data transfer rates via optional 10GbE ports and M.2 B key for 5G modules.
  • Page 15: Product Features

    TPM: TPM 2.0 (support by optional AMO-I029)  1.2.2 Ethernet Chipset:  ® – LAN1/2 Intel i210 ® – LAN3/4 Intel X550 (support by optional AMO-I031) Speed:  – LAN1/2 10/100/1000 Mbps – LAN3/4 100/1000/10000 Mbps Interface: Up to 4 x RJ45  ARK-7060 User Manual...
  • Page 16: Chipset

    BATTERY 3V/210 mAh with WIRE x 1 TPM 2.0 (support by optional AMO-I029) 1.3.2 SUSI 4.2 SUSI API Sequence Control Supported Multi-level WDT (set by Advantech iManager) Watchdog Timer Programmable 1-255 sec/min Hardware Monitor CPU Temperature/input Current/input Voltage System Information Running HR/Boot record...
  • Page 17: Mechanical Specifications

    Mechanical Specifications 1.4.1 Dimensions (W x H x D) 230 x 205 x 390 mm/9.05 x 8.07 x 15.35 in Figure 1.1 ARK-7060 Mechanical Dimensions Diagram ARK-7060 User Manual...
  • Page 18: Weight

    95% @ 40 °C (104 °F) (non-condensing)  1.6.3 Storage Temperature -40 ~ 85 °C (-40 ~ 185 °F)  1.6.4 Safety CB (62368), UL (62368), CCC, BSMI, and UKCA  1.6.5 CE/FCC Class B, CCC, BSMI, and UKCA  ARK-7060 User Manual...
  • Page 19: Chapter 2 Hardware Configuration

    Chapter Hardware Configuration...
  • Page 20: Introduction

    2.2.1 Jumper Description You may configure ARK-7060 to match the needs of your application by setting jump- ers. A jumper is a metal bridge used to close an electric circuit. It consists of two metal pins and a small metal clip (often protected by a plastic cover) that slides over the pins to connect them.
  • Page 21: Jumper Locations

    Jumper Settings 2.2.4.1 Clear CMOS Setting for JCMOS1 JCMOS1 Clear CMOS Settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2.0 mm 180D(M) DIP 2000-13 WS Setting Function (1-2) Normal Operation (Default) (2-3) Clear CMOS ARK-7060 User Manual...
  • Page 22 Fail safe Enable Settings Part Number 1600000402 Foot Print SW_4x2P_50_260x315 Description DIP SW SMD 8P SPST P=1.27mm W=5.4mm KHS42E Setting Function Switch to Pin 1, 2, 3, 4 OFF(Default) Switch to Pin 5, 6, 7, 8 ON ARK-7060 User Manual...
  • Page 23: Bottom Board Jumper List

    Table 2.1: Jumper List M2_SEL1 M.2 B Key Select Function Source Between SATA and PCIE M2_SEL2 M.2 B Key Select Function Source Between USB 3.0 and PCIE NGFF_SMBEN1 M.2 B Key SMB Enable CN10 5G Module power switch ARK-7060 User Manual...
  • Page 24: Jumper Locations

    2.2.6 Jumper Locations ARK-7060 User Manual...
  • Page 25: Jumper Settings

    M.2 B Key Select Function Source Between USB 3.0 and PCIE by M2_SEL2 M2_SEL2 M.2 select function source settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2.0mm 180D(M) DIP 2000-13 WS Setting Function (1-2) Auto detect by card (Default) (2-3) USB 3.0 Floating PCIE ARK-7060 User Manual...
  • Page 26 For 5G Module Power Switch by CN10 Power switch Settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2.0 mm 180D (M) DIP 2000-13 WS Setting Function (1-2) Set Vout 3.805V (For 5G module support +3.805V) (2-3) Set Vout 3.304V (Default) ARK-7060 User Manual...
  • Page 27: Connectors

    Connectors 2.3.1 External I/O Locations Figure 2.2 Front I/O Connector Diagram ARK-7060 User Manual...
  • Page 28 2.3.1.1 COM Port Connector ARK-7060 provides up to 4 x D-sub 9-pin connectors, which offers RS-232/422/485 serial communication interface ports. The default setting is RS-232, the mode RS- 422/485 of ARK-7060 are supported via BIOS settings. Figure 2.3 COM Port Connector Table 2.1: COM Connector Pin Assignments...
  • Page 29 2.3.1.2 Ethernet Connector (LAN) ARK-7060 is equipped with up to 4 x (LAN3/4 are optional by AMO-I031) Ethernet ports. LAN1/2 controllers that are fully compliant with IEEE 802.3u 10/100/1000 Mbps CSMA/CD standards. LAN3/4 are powered by 10GBASE-T controllers provid- ing 10Gb/s of throughput.
  • Page 30 2.3.1.3 Power On/Off Button ARK-7060 has a Power On/Off button with LED indicators on the front side that show “On” (Green LED) and “Off/Suspend” statuses (Orange LED). The Power button sup- ports dual functions: Soft Power -On/Off (Instant off or Delay 4 Seconds then off), and Suspend.
  • Page 31 2.3.1.5 USB 3.0 Connector ARK-7060 supports 4 x USB 3.0 interfaces. The USB interfaces complies with USB UHCI, Rev. 3.0 standards. Please refer to Table 2.5 for its pin assignments. USB 3.0 connectors contain legacy pins to interface with USB 2.0 devices, and a new set of pins for USB 3.0 connectivity.
  • Page 32 Table 2.6: COM2 BMC Dedicated COM Port Pin Assignments Signal Name (RS232) 2.3.1.8 BMC Dedicated VGA Connector Figure 2.10 BMC Dedicated VGA Port Table 2.6: VGA Connector Pin Assignments Signal Name Signal Name Green Blue DDAT H-SYNC V-SYNC DCLK ARK-7060 User Manual...
  • Page 33: Installation

    Installation 2.4.1 Remove Top Cover Unscrew the 7 screws on the top cover. Slightly move the top cover backward, and then lift it up to remove it. ARK-7060 User Manual...
  • Page 34: Memory Installation

    HDD/SSD Installation Unscrew the 2 x screws on the hard drive bay. Install HDD/SSD with 4 x screws on the HDD/SSD tray. Push back the hard drive bay into the system and secure it using the same screws. ARK-7060 User Manual...
  • Page 35: Module Installation/Internal Sim Slot

    Install M.2 B Key module (M2B1 with SIM holder) with bracket according to the M.2 module form factor, and secure in place with screw(s). Install M.2 E key module with 1 x screw (M2E1). Replace the top cover and secure it in place with 7 screws. ARK-7060 User Manual...
  • Page 36: Pciex16 Graphic Card Installation

    Install the graphics card, secure it with a screw (M5X11L) on the bottom nut and connect the cable. If the cable is too short, slightly pull the cable outward. Replace/return the 2 horizontal bars on the top of the system. Replace the top cover and secure in place with 7 screws. ARK-7060 User Manual...
  • Page 37: Mounting Kit Installation

    2.4.7 Wide Operating Temperature Support To make sure the system works well under 0 °C (32 °F) or over 50 °C (122 °F), please ensure your peripherals are i-grade. These support wide temperature opera- tion. ARK-7060 User Manual...
  • Page 38 ARK-7060 User Manual...
  • Page 39: Bios Settings

    Chapter BIOS Settings...
  • Page 40: Introduction

    AMIBIOS has been integrated into motherboards for over two decades. With the AMIBIOS Setup program, users can modify BIOS settings and control various sys- tem features. This chapter describes the basic navigation of the ARK-7060 BIOS setup screens. AMI's BIOS ROM has a built-in Setup program that allows users to modify the basic system configuration.
  • Page 41: Entering The Setup

    BIOS supports your CPU. If there is no number assigned to the patch code, please contact an Advantech application engineer to obtain an up-to-date patch code file. This will ensure that your CPU‘s system status is valid.
  • Page 42: Advanced Bios Features Setup

    Advanced BIOS Setup option by highlighting it using the <Arrow> keys. All Advanced BIOS Setup options are described in this section. The Advanced BIOS Setup screens are shown below. The sub menus are described on the following pages. ARK-7060 User Manual...
  • Page 43 3.2.2.1 Trusted Computing TPM Support  “Enable or Disable” TPM Support. Security Device Support  Enables or Disables BIOS support for security device. ARK-7060 User Manual...
  • Page 44 Physical Presence Spec. Version  Select to Tell O.S. to support PPI Spec Version 1.2 or 1.3. Note some HCK tests might not support 1.3. Device Selection  Select TPM 1.2 or TPM 2.0. 3.2.2.2 Embedded Controller Configuration ARK-7060 User Manual...
  • Page 45 Power Saving Mode  This item allows users to set the board’s power saving mode when off. ARK-7060 User Manual...
  • Page 46 Set Parameters of Serial Port 1. Serial Port 2 Configuration  Set Parameters of Serial Port 2. Serial Port 3 Configuration  Set Parameters of Serial Port 3. Serial Port 4Configuration  Set Parameters of Serial Port 4. ARK-7060 User Manual...
  • Page 47 ARK-7060 User Manual...
  • Page 48 Set temperature threshold of low speed. (Range: 0 ~ 100) Minimum PWM Duty  Set minimum PWM Duty output value. (Range: 0 ~ 100) Temp threshold of stop FAN  Set temperature threshold of stop FAN. (Range: 0 ~ 100) ARK-7060 User Manual...
  • Page 49 3.2.2.3 S5 RTC Wake Settings Wake System From S5  Enable or disable System wake on alarm event. Select Fixed Time, system will wake on the hr::min::sec specified. ARK-7060 User Manual...
  • Page 50 3.2.2.4 UEFI Variables Protection Password protection of Runtime  Control the NVRAM Runtime Variable protection through System Admin Pass- word. ARK-7060 User Manual...
  • Page 51 3.2.2.5 Serial Port Console Redirection Console Redirection  This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services (EMS). ARK-7060 User Manual...
  • Page 52 This supports USB devices with legacy OS such as DOS. When choosing “AUTO”, the system will automatically detect USB devices. It will enable USB legacy mode when a USB device is plugged in and disable USB legacy mode when no USB device is plugged in. ARK-7060 User Manual...
  • Page 53 Mass Storage Devices  Mass storage device emulation type. “Auto” enumerates device according to their media format. Optical drives are emulated as “CD-ROM”', drives with no media will be emulated according to a drive type. 3.2.2.7 Network Stack Configuration ARK-7060 User Manual...
  • Page 54 Network Stack  “Enable or Disable” UEFI Network Stack. 3.2.2.8 NVMe Configuration ARK-7060 User Manual...
  • Page 55 NVMe Configuration  Display device information of NVMe. E.g model name/size. 3.2.2.9 Tls Auth Configuration ARK-7060 User Manual...
  • Page 56 Server CA Configuration  Configure a server CA (Certificate Authority) settings. Client Cert Configuration  Configure Client Cert settings. Client cert configuration is unsupported currently. 3.2.2.10 All CPU Information ARK-7060 User Manual...
  • Page 57: Platform Configuration

    Display the information of each CPU core. 3.2.3 Platform Configuration 3.2.3.1 PCH-IO Configuration ARK-7060 User Manual...
  • Page 58 Serial IRQ Mode  Configure Serial IRQ Mode. State After G3  Specify what state to go to when power is re-applied after a power failure (G3 state). Flash Protection Range Registers (FPRR)  Enable Flash Protection Range Registers. ARK-7060 User Manual...
  • Page 59 – Enable when using Compliance Load Board. – LAN1/LAN2 Controller Enable/Disable on board LAN1/LAN2 from Intel i210 Controller support. – Intel X550 Controller Enable/Disable on board LAN3/LAN4 from Intel X550 Controller support. (LAN3/LAN4 are optional by AMO-I031) ARK-7060 User Manual...
  • Page 60 PCI Express Root Port – Configure PCI Express Root Port Settings. – ASPM PCI Express Active State Power Management settings. – L1 Substates PCI Express L1 Substates settings. ARK-7060 User Manual...
  • Page 61 – PCIe Speed Configure PCIe Speed. Auto is equal to Gen2 or Gen3 depending on DTR soft strap. SATA Configuration  SATA Controller Speed – Indicates the maximum speed the SATA controller can support. ARK-7060 User Manual...
  • Page 62 Determine how SATA controllers operate. Aggressive LPM support – Enables/Disables SATA Aggressive Link Power Management. This item will appear when "AHCI" or "RAID" is selected. – SATA port 1/2/3/4 Enable/disable SATA port. SATA port 3 & 4 are optional. ARK-7060 User Manual...
  • Page 63 If enabled, it indicates that the HDD password unlock in the OS is enabled. – LED Locate If enabled, it indicates that the LED/SGPIO hardware is attached and ping to locate feature is enabled on the OS. ARK-7060 User Manual...
  • Page 64 USB2 PHY Sus Well Power Gating Select 'Enabled' to enable SUS Well PG for USB2 PHY. This option has no effect on PCH-H. – XHCI Wake On Usb Enable Enables/Disables support for XHCI Wake on USB on connect/disconnect. ARK-7060 User Manual...
  • Page 65 Security Configuration – RTC Memory Lock Enable will lock bytes 38h-3Fh in the lower/upper 128-byte bank of RTC RAM. ARK-7060 User Manual...
  • Page 66 “Enable or Disable” the PCH BIOS Lock Enable feature. Required to be enabled to ensure SMM protection of flash. – Force unlock on all GPIO pads If Enabled BIOS will force all GPIO pads to be in unlocked state. 3.2.3.2 Sever ME Configuration ARK-7060 User Manual...
  • Page 67 MCTP Bus Owner  [15:8] bus, [7:3] device, [2:0] function. If all zeros sending bus owner is disabled. 3.2.3.3 System Event Log System Error  Enable/Disable setup options. ARK-7060 User Manual...
  • Page 68 CrashLog Feature  The feature helps collecting crash data from PMC SSRAM. CrashLog On All Reset  Option to invoke CrashLog collection on all reset. Shutdown Suppression  Configures Shutdown Suppression and Log MCA IERR Support. eMCA Settings ARK-7060 User Manual...
  • Page 69 Enable/Disable EMCA Uncorrected SMI for gen2. Corrected Error eLog  Enable/Disable Corrected Error eLog. Memory Error eLog  Enable/Disable Memory Error eLog. Processor Error eLog  Enable/Disable Processor Error eLog. Ubox Error Mask  Mask SMI generation for Ubox Error. ARK-7060 User Manual...
  • Page 70 WHEA Settings WHEA Support  Enable/Disable WHEA support. WHEA Log Memory Error  Enable/Disable Whea Log Memory Error. ARK-7060 User Manual...
  • Page 71 WHEA Log Processor Error  Enable/Disable Whea Log Processor Error. WHEA Log PCI Error  Enable/Disable Whea Log PCI Error. Error Injection Setting WHEA Error Injection Support  Enable/Disable WHEA Error Injection Support. ARK-7060 User Manual...
  • Page 72 Memory Error Enabling Memory Error  Enable/Disable Memory Error. Memory Corrected Error  Enable/Disable Memory Corrected Error. Spare Interrupt  Spare Interrupt Selection. ARK-7060 User Manual...
  • Page 73 IIO Error Enabling ARK-7060 User Manual...
  • Page 74 IIO IRP0 protocol qt overflow underflow error – Enable or disable IIO Coherent Interface protocol queue table overflow or underflow error reporting. – IIO IRP0 protocol rcvd unexprsp Enable or disable IIO Coherent Interface protocol layer received unexpected response or completion error reporting. ARK-7060 User Manual...
  • Page 75 Enable/Disable IIO PCIE AER Spec Compliant. – ITC/OTC CA/MA Errors Enable/Disable Completer Abort and Master Abort (Unsupported Request) on ITC and OTC. – PSF UR Error Enable/Disable Unsupported Request Error on PSF. PMSB Router Parity Erro – Enable/Disable PMSB Router Parity Error. ARK-7060 User Manual...
  • Page 76 PCIe Error Enabling ARK-7060 User Manual...
  • Page 77 PCIE Surprise Link Down Error Enable/Disable PCIE Surprise Link Down Error. Assert NMI on SERR – On SERR, generate an NMI and log an error. Note: [Enabled] must be selected for the Assert NMI on PERR setup option to be visible. ARK-7060 User Manual...
  • Page 78 Gen3 speeds. When an event is triggered, 8GT/s and higher modes are dis- abled. – Gen4 Link Degradation Enable or disable Gen4 link degradation. Applies only when operating at Gen4 speeds. When an event is triggered, 16GT/s and higher modes are dis- abled. ARK-7060 User Manual...
  • Page 79 Error Control Setting – Latch First Corrected Error in KTI Enable or disable latch first corrected error in KTI. – Patrol Scrub Error Reporting Patrol Scrub Error type selection. ARK-7060 User Manual...
  • Page 80 Enable or Disable Software SRAM. Enable will allocate 1 way of LLC; if Cache Configuration subregion is available, it will allocate based on the subregion. Data Streams Optimizer  Enable or Disable Data Streams Optimizer (DSO). Enable will utilize DSO Sub- ARK-7060 User Manual...
  • Page 81: Socket Configuration

    Enable or Disable TCC Error Log. Enable will record errors from TCC flow in memory. Wake System From S5  Enable or disable System wake on alarm event. Select Fixed Time, system will wake on the hr::min::sec specified. 3.2.4 Socket Configuration 3.2.4.1 Processor Configuration ARK-7060 User Manual...
  • Page 82 Hyper-Threading  Enable or Disable Hyper-Threading Technology. Check CPU BIST Result  Enable/Disable BIST (Built-in Self Test) on reset. 3.2.4.2 Memory Configuration ARK-7060 User Manual...
  • Page 83 Memory Frequency  Maximum Memory Frequency Selections in Mhz. If Enforce POR is disabled, user will be able to run at higher frequencies than the memory support (limited by processor support). Do not select Reserved. ARK-7060 User Manual...
  • Page 84 IIO Configuration PCIe Train by BIOS  Assume IIO is strapped for Wait-for-BIOS because straps are unreliable in A-0 Silicon. NTB Link Train by BIOS  This knob enables or disables the BIOS to train the NTB link. ARK-7060 User Manual...
  • Page 85 This option can disable Precision Time Management support in PCI hierarchy. 'Auto' keeps hardware default. PCIe Relaxed Ordering  Enable Relaxed Ordering in PCIe devices where it is supported. Note that in some devices it can be not supported, hardwired to zero. ARK-7060 User Manual...
  • Page 86 IIO Global Performance Tuning – Performance Tuning Mode Select IIO performance tuning mode, where Safe mode contains the default HW state and Performance Enable Mode has the recommended perfor- mance values. ARK-7060 User Manual...
  • Page 87 3.2.4.4 Advanced Power Management Configuration CPU P State Control ARK-7060 User Manual...
  • Page 88 Energy Efficient Turbo Energy Efficient Turbo Disable, MSR 0x1FC [19]. – Turbo Mode Enable/Disable processor Turbo Mode (requires EMTTM enabled too). CPU Flex Ratio Override – Enable/Disable CPU Flex Ratio Programming. – GPSS timer P-state change hysteresis time window. ARK-7060 User Manual...
  • Page 89 Maximum value the floor is allowed to be set to for perf P-limit. – Perf P-Limit Threshold Uncore frequency threshold above which this socket will trigger the feature and start trying to raise frequency of other sockets. Perf P Limit – Enable/Disable Performance P-Limit. ARK-7060 User Manual...
  • Page 90 CPU C State Control Enable Monitor MWAIT – Allows Monitor and MWAIT instructions. – CPU C1 auto demotion Allows CPU to automatically demote to C1. Takes effect after reboot. ARK-7060 User Manual...
  • Page 91 Enable/Disable CPU C6(ACPI C3) report to OS. – Enhanced Halt State (C1E) Core C1E auto promotion Control. Takes effect after reboot. OS ACPI Cx – Report CC3/CC6 to OS ACPI C2 or ACPI C3. Package C State Control ARK-7060 User Manual...
  • Page 92 Default = 0, means [AUTO]. C2 to C3 Transition Timer, PPDN_INIT = 1:10:1:74 Bit[11:0]. – Dynamic L1 PCU_MISC_CONFIG Bit[21] = dynamic L1 enable. – PKG C-state Lat. Neg MSR 1FCh Bit[30] = PCH_NEG_DISABLE. – LTR IIO Input MSR 1FCh Bit[29] = LTR_IIO_DISABLE. Disable = Ignore IIO LTR input. ARK-7060 User Manual...
  • Page 93: Server Management

    Enter the value Between 1 to 30 min for OS Boot Watchdog Timer Expiration. Not available if OS Boot Watchdog Timer is disabled. OS Wtd Timer Policy  Configure how the system should respond if the OS Boot Watchdog Timer expires. Not available if OS Boot Watchdog Timer is disabled. ARK-7060 User Manual...
  • Page 94 3.2.5.1 System Event Log SEL Components  Enable/Disable all features of system event logging during boot. Erase SEL  Choose options for erasing SEL. ARK-7060 User Manual...
  • Page 95  Choose options for reactions to a full SEL. Log EFI Status Codes  Disable the logging of EFI status codes, or log only error codes, or only progress codes, or both. 3.2.5.2 BMC Self Test Log ARK-7060 User Manual...
  • Page 96 Erase Log  Erase log options. When Log is Full  Select the action to be taken when log is full. 3.2.5.3 BMC Network Configuration ARK-7060 User Manual...
  • Page 97 Select to configure LAN channel parameters statically or dynamically (by BMC). Unspecified option will not modify any BMC network parameters during BIOS phase. 3.2.5.4 View System Event Log If any event logs occur during boot up, the event logs will be display at this page. ARK-7060 User Manual...
  • Page 98 3.2.5.5 BMC User Settings Add User  Add user information. Delete User  Delete user information. Change User Settings  Allow change User settings. ARK-7060 User Manual...
  • Page 99: Security

    3.2.6 Security Administrator Password  Set Administrator Password. User Password  Set User Password. ARK-7060 User Manual...
  • Page 100 Secure Boot feature is Active if Secure Boot is Enabled, Platform Key (PK) is enrolled and the System is in User mode. The mode change requires plat- form reset. Secure Boot Mode – Secure Boot mode options: Standard or Custom. ARK-7060 User Manual...
  • Page 101: Boot

    Number of seconds to wait for setup activation key. 65535 (0xFFFF) means indefinite waiting. Bootup NumLock State  Select the keyboard NumLock state. Quiet Boot  Enables or disables Quiet Boot option. Boot Option  Display and select boot devices. ARK-7060 User Manual...
  • Page 102: Save & Exit

    Restore Defaults  Restore/Load Default values for all the setup options. Save as User Defaults  Save the changes done so far as User Defaults. Restore User Defaults  Restore the User Defaults to all the setup options. ARK-7060 User Manual...
  • Page 103: Appendix A Watchdog Timer Sample Code

    Appendix Watchdog Timer Sample Code...
  • Page 104: Ec Watchdog Timer Sample Code

    57h ; Watch dog event flag. out dx,al mov dx, EC_Data_Port mov al, 04h ; Reset event. out dx,al mov dx, EC_Command_Port mov al,28h ; start WDT function. (Stop: 0x29, Reset: 0x2A) out dx,al .exit ARK-7060 User Manual...
  • Page 105 ARK-7060 User Manual...
  • Page 106 No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis- sion from the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. 2022...

Table of Contents