Manitowoc I0320 Technician's Handbook page 129

Indigo series ice machines with r290 refrigerant
Table of Contents

Advertisement

4. Test for line voltage at the individual components.
A. Line voltage is present and the component is
non functional - Replace component
B. Voltage is not present at the component -
Proceed to step 5
5. Refer to wiring diagram and determine wire
location on the 9 pin molex connector for the
component you are testing.
6. Check for line voltage at the control board 9 pin
molex connector.
A. Line voltage at 9 pin connector - Repair
wiring to component
B. No power at 9 pin connector - Replace
control board
Part Number STH038 5/12