Danfoss VLT 6000 Instruction Manual page 5

Adjustable frequency drives
Hide thumbs Also See for VLT 6000:
Table of Contents

Advertisement

1
/
5
Ethernet
Port
Port 2
Configuration
Jumpers
Port 2
Keypad/Display Port
DIP Switches
Access Port
Power switch. Two position on/off power switch.
Portal address label. Identifies factory-set or default portal
addresses.
Port connectors label. Identifies factory-settings for
communication ports 1 and 2. Default setting for port 1 is
unassigned. Default setting for port 2 is EIA-485.
24 VAC connector. Input power for BACLink module.
Format button. Normally not used with BACnet. Contact the
Danfoss Graham service department for information on its use to
clear factory-set programming.
Address rotary switches. Rotary switches used to set BACLink
portal network addresses. Set addresses 01-99 with DIP switch 5
in the +0 position. Set addresses 100-199 with DIP switch 5 in the
+100 position.
Port 1. Preferred port for ARCnet connection. Selectable for
ARCnet or 2-wire EIA-485. Set DIP switch 4 (Port 1) to Other to
enable linking drives with EIA-485 wiring. Set DIP switch 4 (Port
1) to ARC156 for use as ARCnet connector. (See DIP switches.)
6
VLT is a registered Danfoss trademark
"
Ethernet
10 baseT
BACnet
Assigned IP Address
EIA-232
EIA-485
Æ
VLT
2 wire 4 wire EIA-232
Net +
Tx +
Tx
Net -
Tx -
Rx
n/c
Rx +
DTR/RTS
n/c
Rx -
DCD/CTS
Signal Ground
Keypad/Display
Port 1
Connection
Port
Port 2
Connection
Power
Sw1
Off/On
Run
IP Addr
Default/Assigned
Port 1
ARC156/Other
Error
Address
Port 1 Transmit
+0 / +100
Port 1 Receive
Port 2 Transmit
Port 2 Receive
Access
Link
Lan
Port
LED Indicators
1"
Figure 1. BACLink Portal
6"
Ground
Power
24 Vac
Off
On
Single Class 2
Source Only
24 VAC, 60-80 Hz
7.2VA, 0.3A
Use Copper
Conductors Only
BACLink
ô
Open Energy
Management Equipment
Format
10ë s
Address
1ë s
Shield
Port 1
Net -
Net +
Depth: 1
5
/
8
LED indicators. Status indicator lights for functions as labeled.
Access port. Utility port for factory programming, set up, and to
assign the IP address. The access port cannot be used as a
communication point or to download memory to the BACLink.
DIP switches. Two position switches used to enable selection of
IP address, module address, and network type. Sw1 and Sw2
are disabled in VLT communication applications.
Keypad/Display port. Access port for optional keypad.
Port 2. Preferred port for EIA-485 connection to the VLT drives.
The terminal is jumper selectable for 2-wire/4-wire EIA-485 or
EIA-232. Default setting is EIA-485 (2-wire).
Port 2 configuration jumpers. Jumper placement determines
the configuration for EIA-485 (2-wire), EIA-485 (4-wire), or
EIA-232 communication for Port 2. Default is EIA-485 2-wire.
Ethernet port. Ethernet network connector supports 10baseT
network communication with BACLink.
Power Switch
24 VAC
Portal Address Label
1
7
/
"
20
Port Connectors Label
Format Button
Addressing
Rotary Switches
Port 1
"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt 2800Baclink vlt 6000Baclink vlt 2800

Table of Contents