Fireplace Insert Installation

Insert Placement Requirements

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" (915) of the front of the insert (Figure 3 "q").
Insert and hearth must be installed on a level, secure floor
The minimum clearances, facing, and hearth requirements in Figure 3 must be met. Follow the
clearances for the type of fireplace being used – (masonry or zero-clearance-metal).
Side
Wall
k
l
p
q

Hearth Requirements

Must extend 16" (USA) or 18" (Canada) in front of the insert and 8" on both sides.
Must be non-combustible and at least .018" thick (26 gauge)
© Travis Industries
n
m
x
o
100-01233
(for qualified installers only)
Minimum
Masonry
Clearances
Fireplace
13"  331mm 
k Sidewall
9.5"  242mm 
l Side Facing
12"  305mm 
m Top Facing
15.5"  394mm 
n Mantel
16" 407mm
o Front Hearth
(US)
(does not
- - - - - - - - - - -
include insert
18" 458mm
extension "x")
(Canada)
8" 204mm
p Side Hearth
36"
q Front of Insert
915mm
3" 77mm
x Extension Onto
Hearth
9
Z.C. (Metal)
Fireplace
30"  762mm
12"  305mm
12"  305mm
24"  610mm
16" 407mm
(US)
- - - - - - - - - - -
18" 458mm
(Canada)
8" 204mm
36"
915mm
3" 77mm
Figure 3