Stove Installation
Fireplace Requirements
Figure 2 shows the minimum size requirements for the type of fireplace used.
j
i
Insert Placement Requirements
•
The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the
front of the insert
•
Insert and hearth must be installed on a level, secure floor
•
The minimum clearances, facing, and hearth requirements in Figure 3 must be met (follow the clearances for the
type of fireplace being used - either masonry or zero-clearance).
Side
Wall
k
l
p
q
© Travis Industries
Minimum Fireplace Size
h
b
a
d
c
e
g
f
n
m
x
o
100-01234_000
(for qualified installers only)
a
Height (front)
b
Height (rear)
c
Width (front)
d
Width (rear)
e
Depth
f
Hearth Depth*
g
Hearth Width
h
Facing Width
i
Facing Height
with mantel shield
j
Mantel Height
with mantel shield
* This is the distance the insert protrudes from
the fireplace opening plus the required 16" of
hearth extension.
Minimum Clearances
k
Sidewall to Insert
l
Side Facing
m
Top Facing
with mantel shield
n
Mantel to Insert
with mantel shield
o
Hearth (Front)
p
Hearth (Side)
q
Front of Insert
x
Extension onto Hearth
Masonry
Z.C. (Metal)
Fireplace
Fireplace
19-3/4"
19-3/4"
19-3/4"
19-3/4"
24-1/4"
26-1/4"
21-5/8"
23-5/8"
13-1/8"
14-1/8"
26"
26"
40-1/4"
40-1/4"
50-1/4"
48-1/4"
47-1/4"
30-3/4"
39-1/4"
N/A
49-1/4"
42-3/4"
41-1/4"
N/A
Figure 2
Masonry
ZC (Metal)
Fireplace
Fireplace
15"
30"
13"
12"
28-1/2"
12"
20-1/2"
N/A
30-1/2"
24"
22-1/2"
N/A
16"
16"
8"
8"
36"
36"
10"
10"
Figure 3