Drafting Performance; Flue Installation - Travis Industries 1250 Owner's Manual

Masonry fireplace insert
Hide thumbs Also See for 1250:
Table of Contents

Advertisement

Fireplace Insert Installation

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft. Travis Industries can not be responsible for external forces leading to less
than optimal performance.
Leveling Bolt Installation
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install, raise
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert. Adjust
the bolts until they extend the same height as the hearth steps up. After the insert is installed, fine-tune
the leveling bolts to level the insert.
This distance is the
hearth step-up. The
leveling bolts should
stick out this far from the
base of the insert.
Hearth

Flue Installation

The flue must be 6" diameter and a minimum 24 gauge black steel.
Use a starter section and screws to secure the flue to the insert.
© Travis Industries
(for qualified installers only)
Fireplace
100-01233
The leveling bolts go
into the holes at the
rear corners of the
insert.
Figure 5
4110304
11