Blower Replacement - Quadra-Fire CASTILE-MBK-B Owner's Manual Installation And Operation

Quadra-fire castile-b pellet stoves
Hide thumbs Also See for CASTILE-MBK-B:
Table of Contents

Advertisement

F. Blower Replacement
1. Combustion Blower Replacement
NOTE: The convection blower must be removed
before the exhaust blower can be removed.
a. Turn down thermostat, let appliance completely cool and
then unplug appliance before servicing.
b
Remove both side curtains by
not remove) and pull side panels away.
c. Remove 4 screws from the back screen and pivot the top
of the screen toward you leaving the bottom attached to
stove. Figure 34.1.
d. Remove 2 screws to remove the thermostat block and
disconnect the 2 yellow wires.
e. Remove the 2 screws from the power inlet and rotate it
through the hole and out of the screen, leaving the wires
attached.
f.
Disconnect the vacuum hose and both wires (orange
and red) from the vacuum switch attached to the rear
screen.
g. Remove both wires from exhaust blower (blue and
double white).
h. Remove 6 screws using a fl athead screwdriver or a 1/4"
nutdriver. Retain screws for use on replacement blower.
Figure 34.2.
i.
Remove exhaust blower and gasket.
j.
Install new gasket and blower. Discard blower housing
if not needed.
k. Re-install in reverse order.
Side Screws,
Loosen Do Not
Remove
Remove back screws and
bend top back leaving it
attached at the bottom
Figure 34.1
Page 34
loosening 2 screws (do
Side Screws,
Loosen Do Not
Remove
7021-130F
Castile-B FS Pellet Stove
Remove 6 screws
Figure 34.2
Combustion
Blower
Figure 34.3
May 12, 2014