5. Change to clean water or solvent and continue circulating
for another 5 minutes to thoroughly clean the hose, pump
and spray gun.
6. Turn the pressure control knob counterclockwise to its
lowest setting.
7. Turn the PRIME/SPRAY knob to PRIME (
8. Trigger the gun to remove any pressure which may still be
in the hose.
9. Lock the gun by turning the gun trigger lock so that it is
parallel to the gun body.
10. Turn the motor switch to OFF.
Clearing the Gun
1. Remove the spray gun from paint hose using two
adjustable wrenches.
2. Remove the filter housing from the gun. Place the gun
and the filter assembly into a container of water or solvent
to soak.
3. Cover the paint container and set it aside.
4. Clean the spray tip and gun filter with a soft brush.
Assemble the spray tip in the cleaning position with the
arrow pointing to the back of the gun.
5. Attach the paint hose to the gun and tighten using two
wrenches.
6. Turn the motor switch to ON.
7. Unlock gun trigger by turning the gun trigger lock so that it
is parallel to the gun handle.
8. Turn the PRIME/SPRAY knob to SPRAY (
the gun to the side of the cleaning bucket.
9. Trigger the gun and gradually turn the pressure control
knob clockwise to 1/2 pressure. Continue to trigger the
gun for approximately 30 seconds.
10. Turn the pressure control knob counterclockwise to its
lowest setting.
11. Turn the PRIME/SPRAY knob to PRIME (
12. Trigger the gun to remove any pressure which may still be
in the hose.
13. Lock the gun by turning the gun trigger lock so that it is
parallel to the gun body.
14. Turn the motor switch to OFF.
© 1996 Wagner Spray Tech - All rights reserved.
Preparing the Sprayer for Long-term Storage
1. Remove the tip assembly and raise the suction set above
the cleaning solution.
2. Turn the motor to ON.
3. Turn the PRIME/SPRAY knob to SPRAY (
).
4. Turn the pressure control knob clockwise to 1/2 power and
allow the suction tube to run dry.
5. Remove the large suction tube from the inlet valve and
point the gun into the cleaning bucket.
6. Unlock the gun and trigger it into the cleaning bucket until
the hose is pumped dry.
7. Lock the gun and turn the pressure control knob
counterclockwise to its lowest setting.
8. Turn the PRIME/SPRAY knob to PRIME (
9. Lay the sprayer back on its handle so that the inlet valve is
facing upward.
10. Clean the threads of the inlet valve with a damp cloth.
11. Fill the inlet valve with a light household oil. Slowly
increase the pressure to distribute the oil through the pump.
) and point
12. Turn the PRIME/SPRAY knob to SPRAY (
the oil.
13. Replace the large suction tube onto the inlet valve.
NOTE: Proper cleaning and oiling of the pump after
use are the most important steps you can take
).
to insure proper operation after storage.
14. Turn the pressure control knob counterclockwise to its
lowest setting.
15. Turn the PRIME/SPRAY knob to PRIME (
16. Trigger the gun to remove any pressure which may still be
in the hose.
17. Lock the gun by turning the gun trigger lock so that it is
parallel to the gun body.
18. Turn the motor switch to OFF.
19. Remove and clean the suction set filter in clean water or
the appropriate solvent. Use a soft brush. Return the
suction set filter to its original position.
20. Wipe the entire unit, hose and gun with a damp cloth to
remove accumulated paint.