Teledyne Spyder3 SC-34-02K80-00-R User Manual page 59

Spyder3 sc-34 color camera user’s manual
Table of Contents

Advertisement

Spyder3 SC-34 Color Camera User's Manual
Message
Error 04: Incorrect param eter value>
Error 05: Com m and unavailable in
this m od e>
Error 06: Tim eout>
Error 07: Cam era settings not saved >
Error 08: Unable to calibrate - tap
outsid e ROI>
Error 09: The cam era's tem perature
exceed s the specified operating
range>
Teledyne DALSA
Description
This response returned for
·
Alpha received for num eric or vice versa
·
N ot an elem ent of the set of possible values. E.g., Baud Rate
·
Outsid e the range lim it
Com m and is valid at this level of access, but not effective. Eg line rate w hen in
sm art Exsync m od e
Com m and not com pleted in tim e. Eg FPN / PRN U calculation w hen no
external Exsync is present.
Tried saving cam era settings (rfs/ rus) but they cannot be saved .
Cannot calibrate a tap that is not part of the region of interest.
Ind icates that the cam era has shut itself d ow n to prevent d am age from further
overheating.
59
03-032-20116-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spyder3 sc-34-04k80-00-r

Table of Contents