Connecting the server to the mains

In its basic configuration level the server has a hot-plug power supply unit.
A second hot-plug power supply unit can be added to ensure a redundant power
supply. If one power supply unit is defective, the other then guarantees
unimpaired operation. Each hot-plug power supply unit can be replaced during
operation (see the "PRIMERGY RX200 S7 Server Upgrade and Maintenance
Manual").
V
CAUTION!
The server is automatically set to a mains voltage in the range 100 - 240
V. You may only operate the server if its rated voltage range corresponds
to the local mains voltage.
Ê Connect the power cord to the server power supply unit.
Ê Connect the mains connector to an outlet on the rack's socket strip (see also
Technical Manual for the rack).
I
A phase redundancy in the power supply of the server can be set up if
two hot-plug power supply units are installed.
In this case, each of the power supply units is either connected to two
different phases or to two separate circuits of the internal power supply
network.