Connecting The Dual Node Cluster Server To The Mains - Fujitsu PRIMERGY CX420 S1 Operating Manual

Dual node cluster server
Hide thumbs Also See for PRIMERGY CX420 S1:
Table of Contents

Advertisement

Hardware installation
5.4
Connecting the Dual Node Cluster Server to
the mains
The system has two bays for hot-swap power supply units. In the base
configuration, it is fitted with one power supply unit. A second hot-plug power
supply unit can be added to ensure a redundant power supply. If one power
supply unit is defective, the other then guarantees unimpaired operation. Each
hot-plug power supply unit can be replaced during operation (see the
"PRIMERGY CX420 S1 Upgrade and Maintenance Manual").
V
CAUTION!
The Dual Node Cluster Server is automatically set to a mains voltage in
the range 200 - 240 V. You may only operate the Dual Node Cluster
Server if its rated voltage range corresponds to the local mains voltage.
Ê Connect the power cord to the Dual Node Cluster Server PSU.
Ê Connect the mains connector to an outlet on the rack's socket strip (see also
Technical Manual for the rack).
I
A phase redundancy in the power supply of the Dual Node Cluster
Server can be set up if two hot-plug PSUs are installed.
In this case, each of the PSUs is either connected to two different phases
or to two separate circuits of the internal power supply network.
40
Operating Manual
CX420 S1

Hide quick links:

Advertisement