6.1.1.2

Indicators on the control panel

Power-on indicator (three colors)
Lights orange when the server is switched off but mains voltage is
present.
Lights up yellow during power up delay.
I
Lights up green when the server is switched ON.
Flashes green if the server has been switched on and is in standby
mode or if the server is in a sleep state.
HDD/SSD activity indicator (green)
Flashes green when an internal hard disk drive is being accessed.
Global Error indicator (orange)
– Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
– Flashes orange if an error was detected that requires service
intervention.
– Does not light up if there is no critical event.
If the event is still acute after a power cycle, the indicator is activated
after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), on the ServerView Local Service Panel, in the
ServerView Operations Manager or via the iRMC S3's Web
interface.
RX200 S7
If the server is switched off and then immediately switched
on again, a server is only restarted after a power up delay.
This prevents a current overload, for example.
You can set the power up delay (in seconds) in the
BIOS-setup in the Server Menu menu with Power Cycle Delay .