Parts Check List; Power Supply/Cooling Module Procedure - IBM DCS9550 1S1 Installation & Service Manual

Storage expansion unit
Table of Contents

Advertisement

Installation
• Rack mount front flange mounting screws (4 off).
2.2.3.2
Procedure
1
Check for damage.
2
Slide the chassis assembly onto the rack rails until the front flanges engage on the rack.
3
Ensure the chassis is centrally located. If in doubt about correct orientation, the drive bays (at
front) should have their black drive connectors toward the bottom of each bay.
4
Screw the 4 front rack mount screws through the flanges and tighten.
5
Fit and tighten the rear hold down screws ensuring the enclosure is in tight contact to both the
side and top of the chassis to avoid any movement of the chassis in the rack.
2.3
Power Supply/Cooling Module Installation
• Two power supply/cooling modules to be installed in the rear of the enclosure in positions
Warning
2.3.1

Parts Check List

• 2 x AC, 450W Power Supply/Cooling Modules
2.3.2

Power Supply/Cooling Module Procedure

1
Check for damage, especially to the rear connector on the supply.
2
With the PSU handle in the open position (Figure 2–2), slide the module into the enclosure
(Figure 2–3).
18
1 and 5.
Do not remove covers from the power supply unit. Danger of electric
!
shock inside. Return the PSU to Customer Service for repair.
Important
PSU1 (RH rear bay) must be fitted "upside-down"(Figure 2–1). If
necessary, reorient the power cord clip so that the power cord can be
properly retained.
Caution
Handle the module carefully and avoid damaging the connector pins. Do
not install the module if any pins appear to be bent.
IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide