Rear Panel - Inter-m DPA-300S Operation Manual

Digital power amplifier
Table of Contents

Advertisement

Rear Panel

Rear Panel
1
1. C M INS ( C INLET)
It accepts a standard IEC mains cable, provided
2. DC INPUT TERMIN L
Emergency DC back up power (DC24V) terminal. When C power is cut off, The unit will operate with DC
power from spare battery pack.
(DP -SO models are not included with Emergency Power Back Up (DC24V))
3. C POWER REMOTE
This terminal allows the amplifier to be turned on or off from a distance or other device.
4. COOLING VENTS
ir flow is front to back. DO NOT block front or rear air vents.
5. PRIORITY INPUT ND CONT CT CLOSURE
Each amplifier module has 2 audio inputs. The Primary program input, PGM and Priority input, PRI. The
primary regular broadcast program input, PGM is interrupted and over ridden by the Priority input, PRI,
when a contact closure is received on the PRI select terminal. This is Ideal for Emergency message
broadcasting applications.
6. PRI VOLUME CONTROL
It controls the mute level of all other input signal when the PRI IN signal is present.
7. OUTPUT TERMIN L
Speaker Output Terminal with Euro Block.
DP -300S/600S/900S/1200S, DP -300SO/600SO/900SO/1200SO
2
3
AC POWER REMOTE
DIGIT L POWER MPLIFIER
4
7
5
6
8
9
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents