TOTALINE Gold P274-1100 Installation And Operating Instructions Manual page 7

Residential programmable thermostats
Hide thumbs Also See for Gold P274-1100:
Table of Contents

Advertisement

MODEL 1200
THERMOSTAT
HEAT STAGE 2
W/W1
O/W2
RVS COOLING
N/A
Y1/W2
COOL/HEAT
Y/Y2
STAGE 1
G
FAN
R
24 VAC HOT
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
CONNECTION
S2
See Notes 3, 9, and 10 on page 9.
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
Fig. 14 — Single-Speed Packaged Heat Pump with
2-Stage Electric Heat — Model 1200 Thermostat
MODEL 1200
THERMOSTAT
COOL/HEAT
Y/Y2
STAGE 1
O/W2
RVS COOLING
N/A
Y1/W2
HEAT STAGE 2
W/W1
G
FAN
24 VAC HOT
R
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
CONNECTION
S2
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
Fig. 15 — Single-Speed Packaged Heat Pump with
Single-Stage Gas Furnace —
Model 1200 Thermostat
HEATER
SPLICE
CONTROL BOX
BOX
VIO
ORN
WHT
WHT
YEL
GRN
RED
RED
BRN
BRN
RED (TRAN)
PNK
SPLICE
BOX
YEL
ORN
WHT
GRN
RED
BRN
See Notes 3, 9, and 10 on page 9.
MODEL 1300
THERMOSTAT
COOL STAGE 1
Y1/W2
FAN
G
HEAT STAGE 1
W/W1
COOL STAGE 2
Y/Y2
N/A
O/W2
R
24 VAC HOT
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
S2
CONNECTION
ON
SWITCH SETTINGS
A
B
C
D
OFF OFF
ON OFF
Fig. 16 — Two-Speed Air Conditioner with
Single-Stage Furnace — Model 1300 Thermostat
MODEL 1300
THERMOSTAT
COOL STAGE 1
Y1/W2
FAN
G
HEAT STAGE 1
W/W1
COOL STAGE 2
Y/Y2
HEAT STAGE 2
O/W2
24 VAC HOT
R
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
CONNECTION
S2
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF ON OFF
Fig. 17 — Two-Speed Air Conditioner with 2-Stage
or Variable-Speed Furnace —
Model 1300 Thermostat
7
SINGLE-STAGE
TWO-SPEED
FURNACE
AIR CONDITIONER
G
W
Y
R
C
See Note 2 on page 9.
SUGGESTED DIP
TWO-STAGE OR
TWO-SPEED
VARIABLE-SPEED
AIR CONDITIONER
FURNACE
Y1 *
G
W/W1
Y/Y2
W2
R
C
HUM
See Notes 2 and 5 on page 9.
* May not be present on equipment.
Y1
Y2
R
C
Y1
Y2
R
C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gold p274-1200, gold p274-1300

Table of Contents