MODEL 1100
SINGLE-STAGE
THERMOSTAT
FURNACE
24 VAC HOT
R
FAN
G
HEAT STAGE 1
W/W1
COOL STAGE 1
Y/Y2
N/A
O/W2
N/A
Y1/W2
24 VAC COMM
C
N/A
B
S1
OUTDOOR
SENSOR
S2
CONNECTION
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
Fig. 2 — Single-Speed Air Conditioner with
Single-Stage Furnace — Model 1100 Thermostat
TWO-STAGE OR
MODEL 1100
VARIABLE-SPEED
THERMOSTAT
24 VAC HOT
R
FAN
G
HEAT STAGE 1
W/W1
COOL STAGE 1
Y/Y2
N/A
O/W2
N/A
Y1/W2
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
CONNECTION
S2
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
Fig. 3 — Single-Speed Air Conditioner with
2-Stage or Variable-Speed Furnace —
Model 1100 Thermostat
SINGLE-SPEED
AIR CONDITIONER
R
G
W
Y
Y
C
C
See Note 1 on page 9.
SINGLE-SPEED
AIR CONDITIONER
FURNACE
R
G
W/W1
Y/Y2
Y
W2
HUM
C
C
See Notes 1 and 6 on page 9.
MODEL 1100
THERMOSTAT
24 VAC HOT
R
FAN
G
COOL STAGE 1
Y/Y2
HEAT STAGE 1
W/W1
N/A
O/W2
N/A
Y1/W2
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
CONNECTION
S2
ON
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
Fig. 4 — Single-Speed Air Conditioner with
Typical Fan Coil — Model 1100 Thermostat
(Single-Stage Heat Control)
MODEL 1100
THERMOSTAT
TERMINAL BOARD
24 VAC HOT
R
HEAT STAGE 1
W/W1
N/A
O/W2
G
FAN
N/A
Y1/W2
COOL STAGE 1
Y/Y2
24 VAC COMM
C
N/A
B
OUTDOOR
S1
SENSOR
CONNECTION
S2
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
Fig. 5 — Single-Speed Air Conditioner with
Variable-Speed Fan Coil — Model 1100 Thermostat
4
TYPICAL
SINGLE-SPEED
FAN COIL
AIR CONDITIONER
R
G
*
Y
W2
W3
E
C
See Notes 1 and 7 on page 9.
SUGGESTED DIP
* May not be present on equipment.
SINGLE-SPEED
EASY SELECT
AIR CONDITIONER
DH
J1 JUMPER
R
W1
J2 JUMPER
W2
G
Y1
Y/Y2
O
C
See Notes 1 and 7 on page 9.
Y
C
Y
C