Direct Ignition Lighting Instructions - Empire Comfort Systems BVD34FP30(F,L)N-2 Installation Instructions And Owner's Manual

B" vent zero clearance gas fireplace
Table of Contents

Advertisement

DIRECT IGNITION LIGHTING INSTRUCTIONS

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. BEFORE LIGHTING smell all around the appliance area
WHAT TO DO IF YOU SMELL GAS
phone.
2.
Turn off all electric power to the appliance.
automatically lights the burner. Do not try to light the burner
by hand.
4.
Open bottom louver assembly, or open valve access door.
5.
Turn gas line valve to "ON."
in the safety information on reverse. If you do not smell gas,
go to the next step.
7.
Close bottom louver assembly, or close hearth access plate.
2.
Turn off all electric power to the appliance.
3.
Open bottom louver assembly, or open the valve access
door.
NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELEC-
TRONIC IGNITION TO FUNCTION.
Page 24
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
INITIAL START UP GAS LINE PURGE
department.
B. Use only the wall switch or remote control switch to turn the
gas control on/off. Any attempted repairs or adjustments should
C. Do not use this appliance if any part has been under water.
appliance and to replace any part of the control system and
any gas control which has been under water.
8.
Turn on all electric power to the appliance.
9.
If the appliance will not operate, follow the instructions "TO
TURN OFF GAS TO APPLIANCE," and call your service
technician or gas supplier.
4. Turn gas line valve to "OFF."
5. Close bottom louver assembly, or close valve access door.
26534-1-0610