iCanView220/220W User's Guide
iCanTek assumes no responsibility for the damages caused by applying power using
both connectors.
Sensor In/Relay Out : used for connecting sensor, and alarm devices to iCanView220/220W.
Note that the each signal is differentiated by color of cable.
Cable color
red
black
orange
brown
yellow
Sensor Input : Connect external alarm sensors such as the infrared sensors, heat
sensor, magnetic sensors, etc. NC/NO selectable in the admin page.
Relay Output : It is used for connecting external alarm generators such as sirens,
flashing light, etc. When activated, relay output configures a closed circuit.
Please refer to Section 6.1 for more detailed description on the Sensor In and Relay
Out connections.
Reset : There is a factory default switch provided for returning the network camera to factory
default state. Press the switch using tools with sharp tip for a few seconds while power is
applied.

2.4. PC Requirements

AV streaming data received from iCanView220/220W can be decoded or stored in a PC running
the i-NVR program, which is a live monitoring and digital video recording PC compatible application.
Minimum PC requirements:
CPU
Main Memory
Description
Sensor In (+)
Sensor In (-)
Relay out
Relay out
Relay out
Minimum
Pentium III 700
128 MB
Misc.
NC/NO selectable in admin mode.
NC/NO selectable in admin mode.
Normal close
Common
Normal open
Recommended
Pentium IV 1.2G above
256MB above
Rev.1.0 (Aug. 2006)