Honeywell ADEMCO MX8000 Installation And Operation Manual page 14

Digital alarm receiver
Hide thumbs Also See for ADEMCO MX8000:
Table of Contents

Advertisement

MX8000 Installation and Operation Guide
numbers. When using the MX8000-LRR with the VPN feature, 685 or CAPS automation protocol, and
Virtual Receiver Line numbers, assign the MX8000-LRR as line 8.
• When using the 685, CAPS, or CP-220 automation protocol, a limit applies to the number of line cards
that should be used for proper processing by most automation systems.
– The following examples apply when NOT using Virtual Receiver/Line numbers while using 685,
CAPS, or CP-220 automation protocols and are currently supported by most automation systems.
685 OR CAPS MODES - The example below allows up to 3 MX8000-LC3 cards giving 8 usable lines:
For MX8000-LC3 (If using an LRR card, insert it as a replacement for the LC3 in slot 3.)
Line Number
MX8000-LC3 (Y = used)
Device Slot
Alarms Report as Lines:
Line Faults as Line:
• • • • Cards in slot 4 or higher may not be supported by your automation system when using 685, CAPS, or
Notes:
CP-220 automation protocol.
• Cards in slot 4 or higher cannot report alarms or line troubles correctly when ADEMCO 685 or CAPS
automation protocol is chosen.
• Line 9 in slot 3 may not be used when using 685, CAPS, or CP-220.
CP-220 MODE - The example below allows up to 5 MX8000-LC3 cards giving 15 usable lines:
For MX8000-LC3 (LRR card not supported by CP-220 mode.)
Line Number
MX8000-LC3 (Y = used)
Device Slot
Alarms Report as Lines:
Line Faults as Line:
• • • • Cards in slot 6 or higher may not be supported by your automation system when using CP-220
Notes:
automation protocol.
• Cards in slot 6 or higher cannot report alarms or line troubles correctly when CP-220 automation protocol
is chosen.
685 OR CAPS MODES - The example below allows 3 MX8000-LC1 cards only:
For MX8000-LC1 (If using an LRR card, insert it as a replacement for the LC1 in slot 3.)
Line Number
MX8000-LC1 (Y = used)
Device Slot
Alarms Report as Lines:
Line Faults as Line:
• • • • Cards in slot 4 or higher may not be supported by your automation system when using 685, or CAPS
Notes:
automation protocol.
• Cards in slot 4 or higher cannot report alarms or line troubles correctly when ADEMCO 685 or CAPS
automation protocol is chosen.
CP-220 MODE - The example below allows 5 MX8000-LC1 cards only:
For MX8000-LC1 (LRR card not supported by CP-220 mode.)
Line Number
MX8000-LC1 (Y = used)
Device Slot
Alarms Report as Lines:
Line Faults as Line:
• • • • Cards in slot 6 or higher may not be supported by your automation system when using CP-220
Notes:
automation protocol.
• Cards in slot 6 or higher cannot report alarms or line troubles correctly when CP-220 automation protocol
is chosen.
1–6
1
4
7
10
Y
Y
Y
N
1
2
3
4
1,2,3
4,5,6
7,8
1,2,3
4,5,6
7,8
1
4
7
10
Y
Y
Y
Y
1
2
3
4
1,2,3
4,5,6
7,8,9 A,B,C D,E,F
1,2,3
4,5,6
7,8,9 A,B,C D,E,F
1
4
7
10
Y
Y
Y
N
1
2
3
4
1
4
7
1
4
7
1
4
7
10
Y
Y
Y
Y
1
2
3
4
1
4
7
A
1
4
7
A
13
16
19
22
N
N
N
N
5
6
7
8
13
16
19
22
Y
N
N
N
5
6
7
8
13
16
19
22
N
N
N
N
5
6
7
8
13
16
19
22
Y
N
N
N
5
6
7
8
D
D
25
28
31
34
N
N
N
N
9
10
11
12
25
28
31
34
N
N
N
N
9
10
11
12
25
28
31
34
N
N
N
N
9
10
11
12
25
28
31
34
N
N
N
N
9
10
11
12

Advertisement

Table of Contents
loading

Table of Contents