Figure 5-19: Mx8000-Lc3 Ring Options - Honeywell ADEMCO MX8000 Installation And Operation Manual

Digital alarm receiver
Hide thumbs Also See for ADEMCO MX8000:
Table of Contents

Advertisement

MX8000 Installation and Operation Guide
5. When the desired hunt group is flashing press
6. To exit press
.
To Change the Ring Options:
Note: The default ring options will function for most
installations and will not need to be changed.
The ring options menu items (Figure 5–19) have the
following meanings:
MinR (Minimum Ring Period) – This value is the
minimum ringer frequency that is accepted as a valid.
A valid ring frequency must fall between the Minimum
Ring Period and the Maximum Ring Period.
Max (Maximum Ring Period) – This value is the
maximum ringer frequency that is accepted as a valid.
A valid ring frequency must fall between the Minimum
Ring Period and the Maximum Ring Period.
ROff (Ringer Off Time) –- This value is the normal amount of time between rings on the local phone system.
If the value entered in this field is too large for your local phone system, it may cause the system to miss
the beginning of Caller ID information.
Min (Minimum Ringer Off Time) – Caller ID information is normally sent between the first and second ring.
On some phone systems the first ring is sent in 2 bursts with a short pause in between. For proper
handling of caller ID the system needs to be able to determine that these 2 bursts are one ring. The
Minimum Ringer Off Time is used to determine what the minimum interval is between rings so that the
system will treat two burst separated by a brief pause as one ring.
RErr (Ringer Off Error) – To determine when a new call is received, the system will add the value of ROff,
Min, and this value. When the length of time since the last ring exceeds this sum, the ring will be
considered as a new call. This field is used to enter the amount of time to be added to ROff and Min when
determining if a ring is a new call.
Min# (Minimum Number of Ringer Periods – This field is used to define the number of valid rings that must
be received before the system accepts the call as valid (answers).
To Change the Ring Options:
1. Follow the procedures in Section 5.5.2.
5
2. Press
for Miscellaneous Line Options menu.
3. Press
until the display flashes on the <Ring Opt> field.
ENTER
4. Press
.
MENU
5. The display flashes on the Minimum Ring Period (MinR) field.
6. Enter a value from 15 to 99 ms for the Minimum Ring Period.
7. Press
to advance to the Max Ring Period (Max) field.
8. Enter a value from 015 to 100 ms for the Maximum Ring Period.
9. Press
to advance to the Ringer Off Time (ROff) field.
10. Enter a value from 1500 to 8000 ms for the Ringer Off Time.
5–48
ENTER
.
MENU
<Edit Line :01>
5 Misc. Line Opt.
6 Ademco Auto Opt.
7 Line Gain Opt.
Echo Spr=N Call ID=Y
BillDly=N HntGrp=00
<Ring Opt> HngUp=120
<Echo Suppress<=Exit>
MinR=40
ROff=4000 MinO=450
RErr=2200 Min#=05
<Min Ring Period ms
Figure 5–19: MX8000–LC3 Ring Options
­
Max=060