Controller Status Leds; Internal Switches - Ovation 214 User Manual

Table of Contents

Advertisement

Controller Status LEDS

LED
VARIABLE STAGE 1
VARIABLE STAGE 2
STAGE 3
STAGE 4
MIST
CURTAIN OPEN
CURTAIN CLOSE
HEATER 1
HEATER 2
RH COMPENSATION
TEMP RAMP
MIN SPEED RAMP
PROBE DEFECT
ALARM

Internal Switches

Internal switches are located on the inside of
the front cover. All switches are set to OFF when
the controller is shipped from the factory,
#
OFF
1
Unlocked parameters
2
Fahrenheit degrees
3
Probe 2 disabled
4
Probe 3 disabled
5
Probe 4 disabled
6
2 heaters & 0 mist
7
Adjustable hysteresis
8
Cascading heaters
9
De-icing disabled
10
11
12
Switch from OFF to ON to acces the transfer menu
MEANING
Turns on when variable stage 1 fans are on.
Turns on when variable stage 2 fans are on.
Turns on when stage 3 is on.
Turns on when stage 4 is on.
Turns on when the mist output is on.
Turns on when the curtain opens.
Turns on when the curtain closes.
Turns on when heating output 1 is on.
Turns on when heating output 2 is on.
Turns on when a RH compensation function is on.
Turns on when the temperature ramp function is activated.
Turns on when the minimum speed ramp function is activated.
Turns on when a probe is defective.
Turns on when an alarm condition is detected.
ON
Locked parameters
Celsius degrees
Probe 2 enabled
Probe 3 enabled
Probe 4 enabled
1 heater & 1 mist
Fix hysteresis of 2.0°F
Zoned heaters
De-icing enabled
Reserved
Reserved
OVATION 214
OVATION 214 rev.00
7