OVATION 214
Adjusting the Minimum Speed of Stage 1
1
The minimum speed can be adjusted between 10 and 100%.
•
Set the function to STAGE 1 MIN SPEED/RAMP. The mini-
mum speed of stage 1 flashes on the display, alternating
with the letters "SPEEd".
•
Use the adjustment knob to adjust the minimum speed to the
desired value.
NOTE: This speed can only be adjusted if the minimum speed ramp is
disabled (see Minimum Ventilation Ramp chapter).
Adjusting the Minimum Ventilation Timer
2
Time on and Time Off can be adjusted between 0 and 900 seconds,
in increments of 15 seconds.
•
Set the function to STAGE 1 BANDWIDTH/TIMER. The cur-
rent bandwidth of stage 1 flashes on the display "BAnd".
•
Press the push-button. The current Time On of stage 1 flashes
on the display "t. On".
•
Use the adjustment knob to adjust the Time On to the de-
sired value.
•
Press the push-button. The current Time Off of stage 1
flashes on the display "t. Off".
•
Use the adjustment knob to adjust the Time Off to the de-
sired value.
26
OVATION 214 rev.00