FIG. 5 Decor style (AXD) and BB-TP2 cutout dimensions for plasterboard
8. Thread the incoming AXlink and RS-232 wiring through the BB-TP2 knockouts. Refer
toWiring the Touch Panel section on page 8 for more information.
9. Fasten the BB-TP2 to the plasterboard using the expansion screws supplied with the enclosure.
10. Connect the AXlink and RS-232 wiring to the touch panel.
11. Test the connection by reconnecting the AXlink connector to the Central Controller and the
optional RS-232 wiring to the source equipment. The panel beeps on power-up. Before
continuing, disconnect all connections until panel installation is complete.
12. Fasten the touch panel to the BB-TP2 with the #6-32 screws supplied with the en-closure.
13. Place the Decor-style faceplate onto the bezel. You can also secure the faceplate to the bezel
using the four Phillips flat-head security screws.
14. Remove the backing from the adhesive tape strips. Once attached to the faceplate, the security
screws cannot be replaced without removing the overlay.
15. Press the engraved overlay onto the faceplate.
16. Reconnect the AXlink wiring to the Central Controller and RS-232 wiring (optional) to the
external RS-232 device. The touch panel beeps on power-up.